background image

 

 

  

 

 

 

 

 

 

 

 

 

        

WESTELL.COM 

© 2016 Westell Technologies 

 

 

 

 

 

 

  

 

          20 April 2016 Doc. No. 030-300736 rB 

1.877.844.4274 

 

 

 

 

 

 

 

 

 

 

 

     Page 45 of 50 

 

 

Figure 7-7: Navigate to the New Software BIN File 

 

5.

 

Click to select the desired version file. 

6.

 

Click 

  in  the  Specify  INI  File  to  Open  browser  window,  Figure  7-7.  The  Firmware 

Version Check dialog window displays, Figure 7-8. 

 

 

Figure 7-8: Firmware Version Check 

 

7.

 

Click 

 in the Firmware Version Check dialog window, Figure 7-8. The firmware upgrade 

begins, as indicated by the progress bar in the Firmware Version Check window, Figure 7-9. 

Содержание PS51080

Страница 1: ...PRODUCT MANUAL WESTELL COM Westell Technologies 030 300736 rB PS51080 Public Safety Repeater User s Guide...

Страница 2: ...ained from the products described herein or the infringement by such products of any property rights of any persons Use or application of such information or statements is at the users sole risk witho...

Страница 3: ...Users 10 1 2 Application 10 1 2 1 Product Registration Information 10 1 3 Safety Guidelines 11 1 3 1 Important Safety Information 12 1 4 FCC Part 90 Signal Boosters 12 2 Product Overview 13 2 1 Produ...

Страница 4: ...pendix A Important Product Information 48 A 1 Registration Number 48 A 2 Internal Power Supply 48 Appendix B Acronyms and Abbreviations 49 TABLE OF FIGURES Figure 1 1 Product Registration 10 Figure 4...

Страница 5: ...9 File Upload Begins 46 Figure 6 10 Upgrade Complete 46 Figure 6 11 Verify New Software Version 47 Figure 7 1 IP Settings 29 Figure 7 2 Run the Software 30 Figure 7 3 Status Page after clicking conne...

Страница 6: ...nts Purpose This manual contains information and procedures for the operation of the Westell PS51080 Public Safety Repeater Changes that occur after the publishing date may be incorporated by a comple...

Страница 7: ...formation about GUI items alarm status and alarm relay Chapter 4 Product Appearance Provides physical specifications photographs and information about the external and internal repeater configuration...

Страница 8: ...o hardware or software and actions that could result in equipment failure IMPORTANT Additional important information that the user must be aware of but is not related to a hazard NOTE Additional infor...

Страница 9: ...duct in the presence of flammable gases or fumes Lightning danger Do not install or make adjustments to this unit during an electrical storm WARNING Changes and Modifications not expressly approved by...

Страница 10: ...de service interruptions This document assumes the technician or engineer understands the basic principles and functionality involved with repeater and in building systems This guide has been written...

Страница 11: ...tomer s failure to comply with these requirements Grounding This repeater is designed to operate at 110VAC 0 5A maximum current and must always be operated with the ground wire properly connected Expl...

Страница 12: ...gulations section 1 1310 Limits for general population uncontrolled exposure Outdoor antenna must be positioned so that under normal conditions personnel cannot approach closer than 120 cm 4 ft A dire...

Страница 13: ...on The repeater amplifies both the uplink mobile to base and downlink base to mobile signals thus facilitating communications to and from the intended wireless infrastructure With a maximum total of 8...

Страница 14: ...2 Table 2 2 Optional Accessories Quantity Description 1 AC Power Cable 5 feet 10 inches 1 Ethernet cable 6 feet 1 inch 1 Alarm Relay Serial Cable 4 feet 9 inches 1 USB Drive containing the User Manua...

Страница 15: ...Sub Band1 851 861MHz Sub Band2 Frequency selectivity UL DL 40dBc 2MHz Gain UL DL 80dB 1 0dB Sub band balance UL DL 1 0dB Gain adjustment range UL DL 30dB 30dB 1 dB 1dB step AGC Automatic Gain Control...

Страница 16: ...pecifications Notes Dimensions 279 x 425 958 x 81 28 mm L x H x D 11 x 16 77 x 3 2 in L x H x D Weight 7 7 kg 17 lbs Connectors Link service antenna ports N female Power Connectors IEC320 Frame ground...

Страница 17: ...D Lock Detector Isolation UL DL shutdown DC Fail Relay Status UL DL VSWR Manual Amp Displays alarm status UL DL Shutdown Setting 23dBm to 30dBm Use to set the peak power shutdown level UL DL Gain Sett...

Страница 18: ...g Checking isolation data Solidly lit Off Off Normal condition at start up Solidly lit Solidly lit Solid Insufficient data isolation exists between the DL and UL antenna Remove power and re install th...

Страница 19: ...Either method in Table 3 7 would trigger the following alarms Antenna Malfunction PA Failure and Power Failure Table 3 8 Alarm Relay Connections Shutdown Signal Relay Status Notes Normally Open NO pi...

Страница 20: ...WESTELL COM 2016 Westell Technologies 20 April 2016 Doc No 030 300736 rB 1 877 844 4274 Page 20 of 50 4 Product Appearance 4 1 External Configuration Figure 4 1 External Product Configuration...

Страница 21: ...to the 1 3 Safety Guidelines section for proper antenna selection and installation To avoid serious injury death and or damage to the repeater do not install donor or server antennas near overhead pow...

Страница 22: ...less stable and it is more likely to encounter adjacent channel interference When possible shield the rear of a donor antenna by locating it so that any HVAC units and or penthouse structures are beh...

Страница 23: ...d on Repeater Rear 1 If the mounting bracket is attached to the repeater remove it a Grasp the top of the mounting bracket and push firmly down to slide the bracket off the repeater 2 Using the bracke...

Страница 24: ...ur handset uses but that may not always be the case If cables and alignment are acceptable and a problem persists use a spectrum analyzer to examine the signal environment in which the unit is operati...

Страница 25: ...our system you will need to build one 1 Strip the outer serial cable insulation back to expose the inner conductors Figure 5 4 Only the red black and brown conductors will be used You may cut the rema...

Страница 26: ...o the Alarm Relay connector on the PS51080 Figure 5 6 Be sure to fasten the connector screws securely Figure 5 6 Alarm Relay Cable Connected to Repeater 5 Connect the stripped end of the serial cable...

Страница 27: ...ct the PS51080 Public Safety Repeater to an AC power source 1 Remove the cap from the AC 110V power connector on the repeater Figure 5 7 Figure 5 7 Remove the Power Connector Cap 2 Connect the power c...

Страница 28: ...rB 1 877 844 4274 Page 28 of 50 Figure 5 9 Power Cable Connected to Repeater 3 Screw the connector on securely 4 When the repeater is properly set up and ready to have power applied plug the other end...

Страница 29: ...s 192 168 1 150 To connect directly to the repeater from a laptop or PC with a crossover CAT 5E cable or over a LAN change the TCP IP settings on your computer to enable a connection to a host that ha...

Страница 30: ...20 April 2016 Doc No 030 300736 rB 1 877 844 4274 Page 30 of 50 3 Navigate to the location where the PS51080 exe software file is saved Figure 6 2 and double click to run it The Status page Figure 6 3...

Страница 31: ...ess Field editable when Connect button is displayed 2 Connect Disconnect toggle button 3 TX RX LED indicates the state of communication with the repeater and GUI 4 Verify that the IP address in the le...

Страница 32: ...Page Figure 6 4 Status Mode Page continued Item Section 1 System Not User Configurable Informational Only Manufacturer Displays the repeater s manufacturer Repeater Type Displays repeater model S W Ve...

Страница 33: ...tput level of the 700 MHz range Gain dB 800 MHz Displays the downlink gain in the 800 MHz range 800 MHz Output dBm Displays the output level of the 800 MHz range AGC Level dBm Sets the unit s maximum...

Страница 34: ...ut level AGC Level dBm Sets the unit s maximum AGC output value HPA This allows the user to toggle the uplink High Power Amplifier on or off 6 Isolation Isolation Value Measured isolation value air in...

Страница 35: ...normal red alarm Shutdown DL UL Display alarm green normal red alarm DC Fail Display alarm green normal red alarm Relay Status Display alarm green normal red alarm DL VSWR DL Path VSWR check green No...

Страница 36: ...button text to and displays the Control Mode page Figure 6 5 described in this section Figure 6 5 Control Mode Page Item Section 1 700 MHz Uplink Start Frequency Displays the 700 MHz uplink start freq...

Страница 37: ...on On Off AGC Level dBm Sets the unit s maximum ALC output value HPA Downlink HPA On Off 3 Shutdown Allows the shut down level to be set Downlink Shutdown Allows the downlink shut down level to be set...

Страница 38: ...tart frequency End Frequency Displays the sub band 1 downlink end frequency Sub band 2 Uplink Start Frequency Displays the sub band 2 uplink start frequency End Frequency Displays the sub band 2 uplin...

Страница 39: ...eding the specified maximum output level AGC Control Auto Level Control Function On Off AGC Level dBm Sets the unit s maximum AGC output value HPA Uplink HPA On Off 7 Alarm PLL LD Display alarm green...

Страница 40: ...Off Do not measure the isolation Isolation Recheck The isolation check can be performed with the RF on or off Isolation Attenuation This allows control of the isolation attenuation After isolation che...

Страница 41: ...re 1 Insert the included media into your computer and locate the Setup exe file Figure 7 1 2 Double click the file to begin software installation Figure 7 1 Figure 7 1 Setup exe file 3 Navigate to the...

Страница 42: ...1 877 844 4274 Page 42 of 50 4 When the window shown in Figure 7 3 displays click Next The progress window Figure 7 4 displays Figure 7 3 Click Next to Begin Installation Figure 7 4 Installation Prog...

Страница 43: ...WESTELL COM 2016 Westell Technologies 20 April 2016 Doc No 030 300736 rB 1 877 844 4274 Page 43 of 50 Figure 7 5 Installation Complete...

Страница 44: ...tton to display the Control page 2 Click in the IP menu located on the left side of the Control page The Firmware Upgrade progress window Figure 7 6 displays Figure 7 6 Firmware Upgrade Progress Windo...

Страница 45: ...elect the desired version file 6 Click in the Specify INI File to Open browser window Figure 7 7 The Firmware Version Check dialog window displays Figure 7 8 Figure 7 8 Firmware Version Check 7 Click...

Страница 46: ...ete displays in the Firmware Version Check window Figure 7 10 the upgrade is complete Figure 7 10 Upgrade Complete 9 Click located at the bottom left corner of the screen to close the PS51080 software...

Страница 47: ...echnologies 20 April 2016 Doc No 030 300736 rB 1 877 844 4274 Page 47 of 50 11 Verify that the new version of software is indicated in the System section of the Control page Figure 7 11 Figure 7 11 Ve...

Страница 48: ...ril 2016 Doc No 030 300736 rB 1 877 844 4274 Page 48 of 50 Appendix A Important Product Information A 1 Registration Number FCC NVRCSIT51080SP78 A 2 Internal Power Supply The internal power supply for...

Страница 49: ...carrier dBi Decibels relative to isotropic dBm The power ratio in decibels dB of the measured power referenced to one milliwatt mW DC Direct Current DL Downlink FCC Federal Communications Commission...

Страница 50: ...WESTELL COM Westell Technologies 030 300736 rB...

Отзывы: