Section 311-580-20B

030-101527 Rev. B

8

0407IBRB

enter loopback upon loss of signal from the CPE

send AIS to the network upon loss of signal

send Idle to the network upon loss of signal

send AIS-CI to the network upon loss of signal

5.2.2

No matter what action the NIU takes upon detecting

a loss of signal from the CPE, that mode can be remotely over-
ridden by sending a loop-down command to the NIU. Hence,
CPE LOS Override.

5.2.3

Upon detecting the loop-down command, the NIU will

disable the CPE LOS function and operate as if the CPE LOS
function is actually set for disable. During this mode, the NIU
will respond to normal loop-up and loop-down commands. The
CPE LOS Override feature will time out in 20 minutes. At the
end of 20 minutes, the NIU will re-enable the CPE LOS function
and respond accordingly. That is, if a loss-of-signal condition
from the CPE still exists, the NIU will, again, respond according
to how the CPE LOS option is set (LB/AIS/Idle/AIS-CI).

5.3

RAI-CI and AIS-CI Alarms

In this mode, the unit continuously monitors both the signal
from the customer and from the network facility in order to de-
termine what type of alarm signal to send back toward the
network monitoring location. This capability, along with the
uniquely-identifiable Remote Alarm Indication - Customer In-
terface (RAI-CI) and Alarm Indication Signal - Customer
Interface (AIS-CI) signals, allows test personnel to accurately
sectionalize network facility problems versus CPE problems.

5.3.1

RAI-CI

If the unit sees a Remote Alarm Indication signal coming from
the customer equipment (SF or ESF framed), and does not de-
tect an Alarm Indication Signal (AIS), Loss of Frame (LOF) or
Loss of Signal (LOS) on the network, the unit will send a Remote
Alarm Indication (RAI-CI) toward the network if the network
is ESF.

5.3.2

AIS-CI

5.3.2.1

If the unit sees an Alarm Indication Signal coming

from the customer equipment (AIS-CI), and does not detect a
Loss of Frame (LOF), or Loss of Signal (LOS) on the network,
the unit will send a unique Alarm Indication Signal (AIS-CI) to-
ward the network.

5.3.2.2

Both AIS-CI and RAI-CI are backwards compatible

with existing network devices and will appear as normal AIS or
RAI.

5.3.2.3

Upon detecting a loss of signal on the network side of

the unit, the unit will send an Alarm Indication Signal (AIS) to-
ward the customer equipment. The customer equipment, in
turn, will send a Remote AIarm Indication (RAI) signal back to-
wards the network.

6.

PERFORMANCE MONITORING

/

REPORTING

The unit continuously monitors the DS1 bit stream in both the
Network-to-CPE (A-Z) and CPE-to-Network (Z-A) direction
for performance statistics, and maintains these statistics inde-
pendently for each direction. Performance primitives are
collected and stored as performance parameters which are avail-

able for remote retrieval or local retrieval via the front-panel
craft terminal interface port.

6.1

Performance Primitives

Performance primitives are basic error events, or other perfor-
mance-related occurrences, monitored by the unit and stored as
performance parameters.

Line Performance Primitives

Bipolar Violation

BPV

Excessive Zeros

EXZ

Loss of Signal

LOS

Path Performance Primitives

CRC Error (ESF)

CRC6

Frame Bit Error (SF)

FE

Out of Frame

OOF

Severely Errored Frame

SEF

Alarm Indication Signal 

AIS

6.2

Performance Parameters

The unit monitors, processes and stores the span’s performance
primitives as Line, Path and Miscellaneous parameters.

Line Performance Parameters

Coding Violation Line

CVL

Errored Seconds Line

ESL

Severely Errored Seconds Line

SESL

Loss of Signal Seconds Line

LOSS-L

Path Performance Parameters

Coding Violation Path

CVP

Errored Seconds Path

ESP

Severely Errored Seconds Path

SESP

Unavailable Seconds-Path

UASP

Miscellaneous Parameters

Pulse Density Violation Seconds

PDV-SEC

B8ZS Violation Seconds

B8ZS-SEC

Monitored Seconds

MSEC

6.3

Status Register (STAT)

The unit provides a Status Register for both directions of trans-
mission indicating various events that have occurred during a
particular monitoring window. The Status Register consists of
an 8-bit word with a 1" indicating an occurrence of a particular
event.

Event

Bit

Loopback

1

Data incomplete

2

Loss of Signal

3

Reserved

4

Power Loss

5

AIS

6

RAI (alarm yellow)

7

Out of Frame

8

6.4

Event/Alarm Log

The NIU features an Event/Alarm Log that registers various
events occurring during the monitoring period. The log provides
time-stamped entries for the most important types of events
such as loss of signal, power outages, PM registers cleared, alarm
detection, and more. Several different types of events are pos-
sible in the log as listed in the examples of Table 2. The
Event/Alarm Log will retain the 100 most recent events in non-
volatile memory. The Event/Alarm Log can be viewed locally via

Содержание PROACT 3115-80

Страница 1: ...3 and updates Paragraphs 9 2 4 4 through 9 2 4 7 Paragraph 9 2 9 Table 7 Table 11 Table 12 Figure 13 Figure 15 Figure 16 Figure 17 Figure 25 and Figure 27 The Issue B equipment provides the following...

Страница 2: ...es in the Data Link by use of a Test Head without affecting customer payload Remote non intrusive real time reporting of PM pa rameters via 1 second NPRM or SPRM reports in the Data Link per ANSI T1 4...

Страница 3: ...m 24Vdc supplies at certain wireless and PCS Personal Communication Service sites In the local power mode the NIU completes the T1 span simplex power loop and drops negligible span voltage 2 2 2 Span...

Страница 4: ...no net regeneration from input to output In this case the signal is connected directly to the CPE to FAC LBO circuit 3 2 2 CPE to FAC LBO 3 2 2 1 LBO Line Build Out is an artificial line used to meet...

Страница 5: ...not effect the unit s transmission path When the Moni tored Line Coding is set for AMI occurrences of 16 consecutive 0 s will be disregarded and occurrences of B8ZS octets will be re flected in the B8...

Страница 6: ...NIU for the proper duration These control code sequences are listed in Table 1 Function Code Type DS1 T1 Activate 11000 Unframed SF or ESF Loop Up 0001 0010 1111 1111 ESF DATA LINK1 DS1 T1 11100 Unfr...

Страница 7: ...eleased via the craft interface port or 4 when the MAN LB switch is pressed for 5 seconds 5 SECTIONALIZATION ALARM FEATURES The NIU is equipped with features that allow a network moni toring location...

Страница 8: ...m Indication Signal AIS to ward the customer equipment The customer equipment in turn will send a Remote AIarm Indication RAI signal back to wards the network 6 PERFORMANCE MONITORING REPORTING The un...

Страница 9: ...it basis and places the NIU in loopback If the circuit is SF the test con troller must then reconfigure for ESF framing for the duration of the session to allow commands and responses to be exchanged...

Страница 10: ...ast four sec onds of operation This NPRM is inserted into the Data Link by the NIU after the 1 second PRM from the customer CSU that is passed through the NIU Note that the CSU may not generate PRMs o...

Страница 11: ...ustomer back to the network This bit will be a logic 1 if a condition is detected in the signal which would nor mally result in conversion of any bit in a PRM from 0 to 1 Each U2 bit carries informati...

Страница 12: ...tates SPAN LOC Top Edge of PCB Edge Connector 56 pin of PCB Figure 11 NIU Powering Option Location Middle of Side panel s Printed Circuit Board Gray shaded rectangle is the pin jumper P201 When first...

Страница 13: ...en carefully re align and gently re insert the module NIU s DB 9 Connector Baud rate 9600 Number of data bits 8 of start stop bits 1 Parity none Local Echo No Off Warning Bell On Mode VT100 Auto Line...

Страница 14: ...ailable options under the NEW field 9 2 2 1 Saving The Changed Options After configuring the options press S to save the new set tings Note If you enter Esc without saving the system will give a messa...

Страница 15: ...Configures the unit to send SPRM messages SPRM NPRM Configures the unit to send both SPRM and NPRM messages CPE to FAC REGEN Regen Off No regeneration in the CPE to FAC Z A XMT path Regen On Regenerat...

Страница 16: ...ports to the T1 facility and customer interface 9 2 4 2 For each port the screen shows 1 Level LVL of the signal in dB Possible field values are 0 0dB level detected 1 1dB level detected 2 2dB level...

Страница 17: ...pa rameters and options in the loopback path Figure 20 shows the NIU in a single loopback mode when FAC to CPE Regenera tion is Enabled 9 2 4 7 Using the Ctrl D keys simultaneously will cause the NIU...

Страница 18: ...B90 311580 CIRCUIT STATUS CLEI T1S1ABTAAA LVL 0 5dBdsx LVL 0 0dBdsx FRMG SF 3115 80 FRMG UNF UNK SIG OK SIG AIS TO FAC AIS TO CPE REGEN LVL 0 5dBdsx Facility Loopback LVL 8 0dBdsx FRMG SF FRMG SIG OK...

Страница 19: ...The Event Alarm Log can be viewed locally via the craft interface port An example of a typical Event Alarm Log screen is shown in Figure 22 The Event Alarm Log can also be retrieved re motely via TL1...

Страница 20: ...then select Start 3 Select a report number 1 2 3 or 4 to capture data from the SEND DATA TO LOG FILE menu 4 After download is complete select Transfer Capture Text and Stop from HyperTerminal 9 2 10...

Страница 21: ...ill allow the unit to operate directly from T1 metallic spans or from a locally provided 22 to 56Vdc source The NIU is fused on its local power input lead pin 35 to prevent the failure of an individua...

Страница 22: ...ll Once an RMA number is obtained return the defective unit freight prepaid along with a brief problem description to Westell Inc ATTN R G M Department 750 N Commons Drive Aurora IL 60504 7940 Replace...

Страница 23: ...PE to FAC 15 dB WSTTRMTLBO 15 1100 0100 1011 0101 C4B5 22 5 dB WSTTRMTLBO 22 5 1100 0100 1011 0110 C4B6 AB15 dB WSTTRMTLBO AB15 1100 0100 1011 0111 C4B7 AB22 5 dB WSTTRMTLBO AB22 5 1100 0100 1011 1000...

Страница 24: ...TPM None 1100 0101 1101 0000 900 None NPRM C5D0 1900 NPRM Enabled SPRM C5D0 3000 SPRM Enabled SPRM NPRM 2500 SPRM NPRM Enabled Loopback Time out WSTLBTO DIS 900 Disabled p 20 920 20 Minutes 60 1101 01...

Страница 25: ...80 6 dB 7 dB 8dB 120 130 140 12 dB 13 dB 14 dB 180 190 200 18 dB 19 dB 20 dB Facility Level Query 1100 0101 0110 1111 Unframed SF or ESF C56F 20 40 30 50 2 dB 4 dB 3 dB 5 dB 80 90 100 110 8dB 9dB 10 d...

Страница 26: ...tnm optstg cr lf List of Options This is a comprehensive list of command line options Simply use the codes identified in the columns below when configuring command lines OPTION OPTNM OPTSTG Monitored...

Отзывы: