Section 311-580-20B
030-101527 Rev. B
23
0407IBRB
Appendix A
-
Remote Provisioning Codes
Field
Parameter
De-
fault
TL1 Command & Response
(See Note 1)
16-Bit Code
(See Note 2)
Hex Code
Bit Error
Response
Monitored Line
C di
AMI
WSTMONLC=AMI
1100 0101 1011 0001
C5B1
Coding
B8ZS
WSTMONLC=B8ZS
1100 0101 1011 0010
C5B2
Monitored Framing
SF
WSTMONFRMG=SF
1100 0100 1101 0001
C4D1
g
ESF
WSTMONFRMG=ESF
1100 0100 1101 0010
C4D2
CPE LOS Response
None
WSTCLOSRSP=NONE
1100 0101 1010 0001
C5A1
p
LB
WSTCLOSRSP=LB
1100 0101 1010 0010
C5A2
AIS
WSTCLOSRSP=AIS
1100 0101 1010 0011
C5A3
Idle
WSTCLOSRSP=Idle
1100 0101 1010 0100
C5A4
AIS-CI
WSTCLOSRSP=AIS-CI
1100 0101 1010 0101
C5A5
RAI-CI Operation
Disabled
WSTRAICI=DIS
1100 0101 1010 0110
C5A6
p
Enabled
WSTRAICI=ENA
1100 0101 1010 0111
C5A7
Real-Time PM Mode
None
WSTRTPM=NONE
1100 0101 1101 0001
C5D1
NPRM
WSTRTPM=NPRM
1100 0101 1101 0010
C5D2
SPRM
WSTRTPM=SPRM
1100 0101 1101 0011
C5D3
SPRM/NPRM
WSTRTPM=NSPRM
1100 0101 1101 0100
C5D4
CPE REGEN
(FAC
CPE)
Regen Off
WSTRCVRGN=DIS
1100 0100 1010 0001
C4A1
(FAC-to-CPE)
Regen On
WSTRCVRGN=ENA
1100 0100 1010 0010
C4A2
FAC REGEN
(CPE
FAC)
Regen Off
WSTTRMTRGN=DIS
1100 0100 1011 0001
C4B1
100
(CPE-to-FAC)
Regen On
WSTTRMTRGN=ENA
1100 0100 1011 0010
C4B2
XMT LBO
0 dB
WSTTRMTLBO=0
1100 0100 1011 0011
C4B3
(CPE-to-FAC)
7.5 dB
WSTTRMTLBO=7.5
1100 0100 1011 0100
C4B4
(CPE-to-FAC)
15 dB
WSTTRMTLBO=15
1100 0100 1011 0101
C4B5
22.5 dB
WSTTRMTLBO=22.5
1100 0100 1011 0110
C4B6
AB15 dB
WSTTRMTLBO=AB15
1100 0100 1011 0111
C4B7
AB22.5 dB
WSTTRMTLBO=AB22.5
1100 0100 1011 1000
C4B8
FAC-to-CPE LBO
0 dB
WSTRCVLBO=0
1100 0100 1010 0011
C4A3
7.5 dB
WSTRCVLBO=7.5
1100 0100 1010 0100
C4A4
15 dB
WSTRCVLBO=15
1100 0100 1010 0101
C4A5
Loopback Mode
Normal
WSTLBMODE=NORM
1100 0101 1111 0011
C5F3
p
Addressed
WSTLBMODE=ADDR
1100 0101 1111 0100
C5F4
Loopback Time-out
Enable 20
WSTLBTO=20
1101 0101 1101 0001
D5D1
p
Enable 60
WSTLBTO=60
1101 0101 1101 0010
D5D2
Enable 120
WSTLBTO=120
1101 0101 1101 0011
D5D3
Enable 1440
WSTLBTO=24HR
1101 0101 1101 0100
D5D4
Disable
WSTLBTO=DIS
1101 0101 1101 0110
D5D6
Reset to Default
Reset
WSTSDEF=
1100 0101 0111 0110
C576
Circuit ID
ASCII string up to 20 char.
WSTCKTID=<ASCIIstring>
N/A
N/A
Note 1:
TL1 commands are transmitted in the Facility Data Link (FDL) using the command SND-CMD-FDL via the LAPB protocol. The command used to provision the unit is:
ED-T1:::<CTAG>:::<OPTNM>-<OPTSTG>;. Example of the TL1 command to change the XMT LBO of the unit is: ED-T1::::::WSTTXLBO=7.5; The unit then will respond to the
command with TL1 command in this example 7.5.
Note 2:
All 16-bit command codes must be sent to the unit for minimum of five seconds in order to provision the unit. In order to see a bit-error response from the unit, the command code
must be present for a minimum of 10 seconds. The unit will respond to the command with bit errors after the 10-second time frame.
Table 11.
Remote Provisioning Codes