Noran Tel
Page 12 of 16
a subsidiary of Westell, Inc
portions of the SiteVu’s configuration are
included when the file is downloaded. These
configuration sections can then be uploaded to
another SiteVu.
Figure 8-2 Configureation File Settings Menu
The
Enable File Transfer
menu item indicates
whether this file can be used for downloading
or uploading the SiteVu remote unit’s
configuration.
The
File Name
menu item can contain up to 24
characters maximum plus a 3 character
extension after the period. The default 3
character extension is svu. The user can enter
their three character extension by typing a
period and the extension. The characters can
be any letter, number or other character. Also,
the filename field is case sensitive.
When enabled, the following portions of the
SiteVu’s configuration will be included in the
file.
•
AI, DI, and DO settings - this includes
the entire configuration for Analog
Inputs, Digital Inputs and Digital Outputs
excluding the sensor descriptions.
•
Sensor descriptions - this includes the
sensor descriptions for Analog Inputs,
Digital Inputs, and Digital Outputs
•
Security Settings - this includes all the
settings in the Security Menu.
•
Communication settings - this includes
all the settings in the Communication
Settings Menu.
•
System properties - this includes all the
settings in the System Properties menu.
8.2 Firmware File Settings (6)
The firmware in the SiteVu can be updated
remotely using the menu options available in
Figure 8-3.
Figure 8-3 Firmware File Settings Menu
The
Enable File Transfer
menu item allows the
user to enable or disable the remote firmware
update functionality on the remote unit. When
enabled and the user uploads the new firmware
using the filename configured in the File Name
menu item, the remote unit begins the process
of installing the new firmware and then
restarting when completed. This process takes
approximately one minute before the new
firmware is installed and the SiteVu remote unit
is available again.
The
File Name
menu item can contain up to 24
characters maximum plus a 3 character
extension after the period. The default 3
character extension is svu. The user can enter
their three character extension by typing a
period and the extension. The characters can
be any letter, number or other character. The
filename field is case sensitive as well.
8.3 Log File Settings (7-8)
The log files can be downloaded remotely
using the TFTP protocol. The options available
for setting up the file transfer are shown in
Figure 8-4.
Figure 8-4 Log File Settings Menu
The
Enable File Transfer
menu item must be
enabled to download a selected log from the
SiteVu in tab-separated value format.
The
File Name
menu item can contain up to 24
characters maximum plus a 3 character
extension after the period. The default 3
character extension is tsv. The user can enter
their three character extension by typing a
period and the extension. The characters can