background image

 
 

 

Noran  Tel     

 

 

 

 

Page 12 of 16

   

 

 

  

 

a subsidiary of Westell, Inc

 

 

portions of the SiteVu’s configuration are 
included when the file is downloaded.  These 
configuration sections can then be uploaded to 
another SiteVu. 
 

 

Figure 8-2 Configureation File Settings Menu

 

 
The 

Enable File Transfer

 menu item indicates 

whether this file can be used for downloading 
or uploading the SiteVu remote unit’s 
configuration.   
 
The 

File Name

 menu item can contain up to 24 

characters maximum plus a 3 character 
extension after the period.  The default 3 
character extension is svu. The user can enter 
their three character extension by typing a 
period and the extension.  The characters can 
be any letter, number or other character.  Also, 
the filename field is case sensitive. 
 
When enabled, the following portions of the 
SiteVu’s configuration will be included in the 
file.   

  AI, DI, and DO settings - this includes 

the entire configuration for Analog 
Inputs, Digital Inputs and Digital Outputs 
excluding the sensor descriptions. 

  Sensor descriptions - this includes the 

sensor descriptions for Analog Inputs, 
Digital Inputs, and Digital Outputs  

  Security Settings - this includes all the 

settings in the Security Menu. 

  Communication settings - this includes 

all the settings in the Communication 
Settings Menu. 

  System properties - this includes all the 

settings in the System Properties menu. 

8.2  Firmware File Settings (6) 
The firmware in the SiteVu can be updated 
remotely using the menu options available in 
Figure 8-3. 

 

 

Figure 8-3 Firmware File Settings Menu

 

 
The 

Enable File Transfer

 menu item allows the 

user to enable or disable the remote firmware 
update functionality on the remote unit.  When 
enabled and the user uploads the new firmware 
using the filename configured in the File Name 
menu item, the remote unit begins the process 
of installing the new firmware and then 
restarting when completed.  This process takes 
approximately one minute before the new 
firmware is installed and the SiteVu remote unit 
is available again. 
 
The 

File Name

 menu item can contain up to 24 

characters maximum plus a 3 character 
extension after the period.  The default 3 
character extension is svu. The user can enter 
their three character extension by typing a 
period and the extension.  The characters can 
be any letter, number or other character. The 
filename field is case sensitive as well. 

8.3  Log File Settings (7-8) 
The log files can be downloaded remotely 
using the TFTP protocol.  The options available 
for setting up the file transfer are shown in 
Figure 8-4. 
 

 

Figure 8-4 Log File Settings Menu

 

 
The 

Enable File Transfer

 menu item must be 

enabled to download a selected log from the 
SiteVu in tab-separated value format. 
 
The 

File Name

 menu item can contain up to 24 

characters maximum plus a 3 character 
extension after the period.  The default 3 
character extension is tsv. The user can enter 
their three character extension by typing a 
period and the extension.  The characters can 

Содержание Noran Tel SITE VU MINI N04005-SVU/L0806

Страница 1: ...emote units using the local port service port via USB and or using the Telnet option over Ethernet Any VT100 compatible Telnet client software and serial communication software may be used to communic...

Страница 2: ...n is dropped The user must wait a set amount of time Security Lock Out time before trying to reconnect via Telnet After a successful login the Site Vu Main Menu is displayed If 3 failed logins occur f...

Страница 3: ...5 DIGITAL OUTPUTS 5 9 6 CURRENT ALARMS 6 9 7 SECURITY 7 10 7 1 USER PROPERTIES MENU 1 5 10 7 2 SECURITY LOG MENU 6 10 7 3 ACCESS CONTROL LIST MENU 7 11 7 4 SECURITY LOCKOUT MENU ITEMS 8 10 11 8 FILE T...

Страница 4: ...item that contains a colon and presses the Enter key the menu item selected is displayed along with its previous setting Also a prompt is displayed for the user to enter a new value for the setting Th...

Страница 5: ...nit to send SNMP v1 traps to Network Management Station s Figure 1 3 displays the menu item settings for this menu Figure 1 3 SNMP Settings Menu The Allow SNMP Read menu item can be enabled to allow a...

Страница 6: ...ge the default port for the Telnet server A user may want to change this port for access through firewalls and or to obfuscate the location of the Telnet server on the SiteVu remote unit The Telnet In...

Страница 7: ...to add a de bounce time to eliminate jitter on the sensor This value can be anywhere between 1 10th of a second to 6553 1 seconds 109 minutes Refer to the Digital Input sensor section in the hardware...

Страница 8: ...outputs a voltage between 0 50mV Rather than displaying a voltage and using alarm points in the mV range the value can be converted to Amperes instead o Multiplier 400A 50mV 8000 o Range 0 125mV o Of...

Страница 9: ...ensor is controlled by an alarm event When AUTO is set the state of the relay SET or CLEAR is displayed after the AUTO setting When the digital output changes state a SNMP trap is automatically sent a...

Страница 10: ...ACCESS READ ACCESS or READ WRITE ACCESS The read privilege allows that user to view all the menus in that section The read and write access privilege allows a user to read the menus and change the con...

Страница 11: ...hat are currently locked Also a failed login Security Log item is created in the Security log menu item A username becomes locked if the user tries to login with the correct username but not the corre...

Страница 12: ...tings 6 The firmware in the SiteVu can be updated remotely using the menu options available in Figure 8 3 Figure 8 3 Firmware File Settings Menu The Enable File Transfer menu item allows the user to e...

Страница 13: ...cessed through this menu Figure 10 1 System Properties Menu The Current time item allows a user to set the time for the remote unit The time entered is based on the Time Zone offset from UTC menu item...

Страница 14: ...t regular intervals and store the results in a tab separated value file tsv Initially data is logged every second After the first 5 minutes it is logged less frequently at 1 minute intervals The Site...

Страница 15: ...puts it on the user s computer The first two steps essentially copies the configuration from one SiteVu remote unit and places that same configuration on the second remote unit Downloading with XMODE...

Страница 16: ...tput Number Low 11 Output State on Alarm Low 12 High Alarm enable 13 Send SNMP Trap High 14 High Alarm Point 15 Return Point High 16 Severity High 17 Digital Output Number High 18 Output State on Alar...

Отзывы: