MAINTENANCE AND TROUBLE-SHOOTING
MONITOR CARE
Keep the monitor out of direct sunlight or the LCD display may be damaged. The monitor can be cleaned using
a soft, dry cloth. Do not allow liquid to come in contact with the monitor. Remove the batteries when storing the
CARDIO GLIDE.
REPLACING THE BATTERIES
If the display of the Monitor (1) becomes dim, the two
“AA” batteries should be replaced.
Remove the battery
cover from the back of the Monitor. Remove the two old bat-
teries, making sure to note which way each battery is turned.
Insert two new batteries.
Reattach the battery cover to the back of the Monitor (1).
ADJUSTING THE MAGNET AND REED SWITCH
If the monitor does not function properly, the Magnet (27)
and Reed Switch (15) should be checked. Pivot the Pedal
Frame (7) until the Magnet is aligned with the Reed Switch.
See the inset drawing. Loosen the indicated #8 x 3/4” Screw
(18). Slide the Reed Switch (15) slightly closer to the Magnet
(27). Tighten the #8 x 3/4” Screw. Exercise on the CARDIO
GLIDE for a moment. Repeat until the monitor displays cor-
rect feedback.
Make sure that the Magnet does not hit the
Reed Switch.
LUBRICATING THE CARDIO GLIDE
The ends of the Link Arms (4) should be oiled every six
months. Apply a few drops of light multi-purpose oil between
the Link Arms and the dome caps in the indicated locations.
7
27
18
15
27
7
15
Apply Oil
4
8
1
“AA” Batteries
Battery Cover