GRANUDOS 45/100 PLUS V70 Touch
Index: 03
Change date: 25.04.2018
Operating instructions no.: BA SW 001-03 Granudos 45-100 PL V70T.docx
Page 53 of 92
Reset
The current programme is stopped and the fault currently shown is deleted. Then
the programme restarts. The fault is again displayed after a delay of 6 seconds
when the fault is still pending.
Dosing Off/On
For switching off the dosing during the initial operation, shut-down or maintenance.
The dosing of chemicals is switched off, the dosing motors for chlorine and acid
flash in yellow, the filling continues running with plain water. The button now shows
Dosing off . Press this button to resume regular dosing operations.
Menu
Access to the main menu with sub-programmes, settings for test programmes,
service requires that the operation is first terminated by using the red Stop button.
A detailed description of the “Main menu” sub-programmes see
Sections 6.2.4 to
Alarm list
The full test of fault messages is shown in this alarm list. Example: The rinsing tray
symbol on the display is flashing in red when the rinsing tray is faulty and a short
descriptor of the first fault that occurred in this context is shown flashing inside the
rinsing tray symbol. The alarm list does not contains the full text of the fault
message. Once the fault has been removed, use Reset to return to the operating
mode.
Figure 37, Main menu