GRANUDOS 45/100 PLUS V70 Touch
Index: 03
Change date: 25.04.2018
Operating instructions no.: BA SW 001-03 Granudos 45-100 PL V70T.docx
Page 29 of 92
Feed system:
91.
Distribution plate
92.
Installation plate
93.
Screw connections to the feed
pump
94.
Manometer with pressure
transmitter
95.
Handle
Procedure:
1.
The
distribution
plate
was
disassembled for transport. Place
the distribution plate (91) onto the
lower mounting plate (92) and
fasten it to the frame.
2.
Connect the screw connections
(93) to the feed pump behind the
mounting plate.
3.
Screw in the pressure transmitter
together with the pre-installed
manometer (94) into the T-piece.
4.
The 4 handles (95) at the corners of
the collection tray can be cut off.
4.3.3
Installation of the buffer tank (buffer tank option) with/without protective
tray
Place the protective tray onto a suitable, level foundation in the device room and align
it. Place the empty buffer tank into the protective tray and check that it stands firmly.
The buffer tank may only be operated with a suitable protective tray. (protective tray
possibly provided by the customer)
Ensure that there is sufficient free space for operation and maintenance of the device.
Figure 19, Feed system, front,
and rear side
91
95
94
93
92