44
Integrated Web Server
Signal Selection
All of the internal camera’s columns are searched for signals. If two or more signals are
detected in a single column, the user can specify the order in which the signals are read
out as distance value Z.
NOTE!
This setting can be used to reduce reflection and other laser line interference.
The following selection criteria are available:
• Strength: The brightest signal is read out as signal 1.
• Width: The widest signal is read out as signal 1. A wider signal occurs when the
laser light penetrates more deeply into the object’s surface. Signal width is not
shown in the profile display.
• First: The first signal in the profile display of the integrated website is read out as
signal 1.
• Last: The last signal in the profile display of the integrated website is read out as
signal 1.
Trigger Settings
Profile Mode
• Dynamic: The profile is recorded for as long as the trigger signal is applied.
Figure 1: “Dynamic” Profile Mode
Number of profiles
Trigger signal
Profile Mode
• Fixed After the “Number of Profiles” has been selected, precisely this number of pro-
files is recorded after the start event occurs (trigger, software command), and profile
recording is stopped automatically until the next start event occurs (see also “profile
enable” pin function).
Figure 2: “Fixed” Profile Mode
Number of profiles
Trigger signal