30
IO-Link
Window Teach-In
Sensor
Object
Teach-in distance
Switching
point
Window size
Function size of the
near switching point
Function size of the
far switching point
Switching point
50 – 10,000 mm
NOTE!
If a distance range has been set, the switching point can
be set within the set distance range only.
5,000 mm
Window’s near
switching point
Distance from the set center of the window to the window’s switching
point that is close to the sensor.
The window can be set so that it extends from the sensor’s minimum
setting range to its maximum setting range. The possible minimum
and maximum settings result from the center of the window set in a
particular instance.
30 mm
Window’s far
switching point
Distance from the set center of the window to the window’s switching
point that is far away from the sensor.
The window can be set so that it extends from the sensor’s minimum
setting range to its maximum setting range. The possible minimum
and maximum settings result from the center of the window set in a
particular instance.
30 mm
Hysteresis
Hysteresis is the difference between the switch-on and switch-off
point.
5 – 1,000 mm
15 mm