9
Long-Range Laser Distance Sensors
Order No.
Technical Data
P2PY
101
109
105
103
106
107
108
Setting range
50…10.000 mm
—
Measuring range
—
50…10.000 mm
Switching hysteresis
< 15 mm
—
Current consumption
(operating voltage
= 24 V)
< 35 mA
< 40 mA
Switching frequency
50 Hz *
—
Response time
15 ms *
—
Measuring rate
—
100/s *
Acceleration Sensor
Yes
Yes
Connection
diagram no.
243
241
242
Connection type
M12×1; 4/5-pin
M12×1; 4/5-pin
Interchangeable
optical lens
—
Yes
—
Yes
—
ECOLAB
Yes
—
Yes
—
Yes
FDA compliant
Yes
—
Yes
—
Yes
Output function
2× PNP NO
PNP NC,
PNP NO
2× PNP NO
2× NPN NO
Analog
0–10 V
Analog
4–20 mA
MTTFd
(EN ISO 13849-1)
543,71 a
502,44 a
511,24 a
* Depends on mode, see chapter
“3.4 Mode-Dependent Data” on page 10
3.2 Warm-up phase
The warm-up phase lasts 6 minutes. The switching on drift during that time can be seen in the following
diagram.
0
60
120
180
240
300
–7
–5
–6
–4
–3
–2
Time in sec.
Typ. deviation in mm
–1
Switching On Drift
360
0
NOTE!
Specifiations related to the measured value without load. For the analog versions this spec-
ification can deviate due to the load on the analog output.