28
IO-Link
I3
Laser-Off Input
The sensor’s emitted light is deactivated as long as the input is activated.
The sensor does not supply a measured value and sets the status to
“No signal.”
Teach-In Input
Teach-in
The outputs (switching outputs/analog output) can be set by following the same
procedure as with the teach-in key (see section 6). An activated input corre-
sponds to a depressed teach-in key.
Locking
If 18 – 30 V DC is continuously applied to the teach-in input, the teach-in key is
locked and protected against inadvertent changes, like the input signal.
Acceleration Sensor Reset Input
The status message for the acceleration sensor is reset.
Deactivated
The pin is deactivated.
Laser-off input
7.1.2.2 Output Functions
The output functions are used to set the physical outputs.
Function
Possible Settings
Default
PNP/NPN/
push-pull
PNP
NPN
Push-Pull
PNP
NC/NO
NO
Light switching
The output is high when the condition has been fulfilled depending on
the setting (switching point, warning, error).
NC
Dark switching
The output is low when the condition has been fulfilled depending on
the setting (switching point, warning, error).
NO
On-delay
0 – 10,000 ms
0 ms
Off-delay
0 – 10,000 ms
0 ms