WaRNING:
To prevent accidental startup, always disconnect the tool from the air supply before
carrying out any adjustments, service or maintenance.
ClEaNING
Keep the tool free of dirt and dust. After each use, wipe the tool clean with a damp towel and some soft soap.
Blow the tool clean using compressed air. Only use non-flammable cleaning solutions to wipe exterior of the
tool if necessary. do not soak tool with cleaning solutions. Such solutions can damage internal parts.
lUbRICaTION
routine lubrication of the tool is required for best performance. An automatic in-line mist lubricator is recom-
mended to supply lubricant to the tool’s inlet automatically. if tool is used without an in-line lubricator, place
a few drops of 30W non-detergent air tool oil into the tool’s air inlet at the beginning of each workday or after
about 2 hours of continuous use
Also, make sure to lubricate the attachment receiver with a few drops of air tool oil at the beginning of each
workday or after about 2 hours of continuous use. Lack of lubrication can damage the tool and attachment.
INSPECTION
Before each use, inspect the general condition of the tool. Check for:
• Loose hardware,
• Misalignment or binding of moving parts,
• damaged hose or leaks,
• Cracked or broken parts, and
• Any other condition that may affect its safe operation.
do not operate if any portion of the tool, trigger, or locking sleeve is damaged, inoperable, disconnected, or
altered. Any issues with the tool such as leaking air, damaged parts, or missing parts should be repaired or re-
placed before use.
aIR COMPRESSOR
All compressed air contains moisture and other contaminants that are detrimental to internal components of the
tool. dirt and water in the air supply are major causes of pneumatic tool wear. regularly drain water and con-
taminants out from the compressor. An in-line filter is recommended to remove most of these contaminants and
prolong the life of the tool.
Follow the instructions with your compressor and filter for installation and operation.
STORaGE
Store the unit and accessories in a dark, dry, frost-free and well ventilated place, out of the reach of children. The
ideal storage temperature is between 40 to 86°F (5 and 30°C).
PRODUCT DISPOSal
used pneumatic tools contain recyclable materials and should not be disposed with household waste. Please take
this product to your local recycling facility for responsible disposal and to minimize its environmental impact.
MAiNTENANCE
12
Содержание 61635