Table 3: LS-14 Troubleshooting (Continued)
Issues
Possible Causes
Solutions
The regulator is leaking.
The poppet assembly may need to be
replaced.
Check the poppet assembly and the seat
on the regulator. Replace as necessary.
Refer to the
Installation, Operation, and
Maintenance
(IOM)
Manual
for the
regulator for instructions on maintaining
the regulator.
The mixer is not working properly.
The pneumatic supply may be too high,
too low, or not operating.
The hydraulic supply may be too low or
not operating.
The relief and check valve in the
hydraulic line have failed.
Inspect the pneumatic supply and
regulator to ensure that air is supplied at
the appropriate pressure.
Inspect the electro-hydraulic unit (EHUC).
Add hydraulic oil as necessary. Ensure that
hydraulics is supplied at the appropriate
pressure. If the EHUC is not operating,
refer to the
Installation, Operation, and
Maintenance
(IOM)
Manual
for the EHUC.
Maintain the relief and check valve. Refer
to the
Installation, Operation, and
Maintenance
(IOM)
Manuals
for the relief
and check valve for instructions.