2.1 Before You Begin
After unpacking the unit, check the equipment for compliance and any damage that may have occurred during shipment.
Immediately contact a Welker representative if you received damaged equipment.
When sealing fittings with PTFE tape, refer to the proper sealing instructions for the brand used.
2.2 Installation
1.
Locate the skid as close as possible to the sample point.
2.
Mount the skid to a flat, level surface, such as a concrete slab.
3.
Connect a grounding wire to the grounding lug on the skid to safely ground the system (
, or
).
4.
Ensure that all valves on the LS-14 are closed (
,
, or
).
5.
Using appropriately sized tubing, connect from purge/return valve D to the pipeline (
,
, or
).
6.
As necessary, connect a sampler to the sample inlet on the manifold block (
,
, or
).
7.
As necessary, connect from the solenoid to the sampler (
,
, or
).
8.
Apply pressure from the sampler to the manifold block. Check for leaks and repair as necessary.
9.
As necessary, fill the reservoir of the air lubricator/oiler to the maximum fill line with oil compatible with the seal
material (
). Refer to the
Installation, Operation, and Maintenance
(IOM)
Manual
for the air lubricator/oiler for
instructions on filling the reservoir and for recommendations on the type of oil to use.
Figure 8: Pneumatic Supply Conditioning System
10.
As necessary, connect a clean, dry pneumatic supply to the pneumatic supply inlet on the regulator (
11.
As necessary, open the reservoir cap on the EHUC, and then fill the EHUC with the appropriate volume of ISO 46
hydraulic oil (
).
SECTION 2: INSTALLATION & OPERATION
14
IOM-131
MODEL: LS-14