29
IOM-131
MODEL: LS-14
REV: F
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331
Top Cap
Figure 19: Top Cap Maintenance Diagram
49.
Replace the O-ring on the top cap.
Reassembling the LS-14
50.
Place the top cap onto the actuator cylinder.
51.
Insert the actuator tie bolts into the top cap.
52.
Following a cross-bolting sequence, tighten the actuator hex nuts (
).
53.
As necessary, tighten all tie bolts to the correct torque (
).
54.
Connect the tubing to the top cap.
55.
Connect the tubing between the inert gas supply tank and the pre-charge end cap.
56.
Check the system for loose fittings. Tighten any loose fittings and replace ferrules where necessary.
57.
Install the system according to the instructions in
, and
Section 2.3, Preparing for Sampling
Check valves for leaks and repair as necessary during reinstallation.