Service and repair guide
If the temperature reading is unstable:
1.
Disconnect and isolate the appliance from the electricity supply.
2.
Take protective measures to ensure the power cannot be switched on again.
3.
Allow the appliance to cool down.
4.
Remove the side and top panels of the casing.
5.
Check the cavity temperature sensor wire and connections.
6.
If the wire and connections are working properly replace the cavity temperature sensor (see
7.
Refit the panels of the casing.
8.
Switch ON the appliance and repeat the test procedure as described above.
9.
If the temperature is still unstable repeat steps 1 to 3, replace the SRB (see
Section 3F. - Replacing components
) and
repeat step 6.
Reuse the existing PM (Personality Module) on the new SRB (enter serial number on reboot).
Soak test: checking the cavity integrity
The Soak test is used to check the overall functionality of the oven while in full operation.
1. Place an oven/microwave safe container with approximately 2 liters of water into the cavity.
2.
Close the appliance door and select ‘Soak Test’
from the Service Mode oven
tests.
3. Run the test (30 minutes at maximum oven temperature, 50% microwave
power, and maximum fan speed), carefully checking the appliance casing,
joints and door seal for signs of steam or water escaping from the cavity.
If necessary, rectify any leaks and repeat the test.
4. Safely remove the container from the cavity.
Содержание Merrychef eikon e1s
Страница 11: ...11 eikon e1s Service and repair guide Section 1 Safety ...
Страница 43: ...43 eikon e1s Service and repair guide Section 2 Operations and Installation ...
Страница 82: ...82 eikon e1s Service and repair guide Section 3 Service and Repair ...
Страница 147: ...147 eikon e1s Service and Repair Guide Circuit diagrams ...