Replacing the Rinse Aid Canister
1.
Risk of skin, eye, and respiratory tract irritation
■
Do not let the rinse aid come into contact with your eyes, skin, or
mucous membranes.
■
Do not inhale the rinse aid's vapors or mist.
■
Wear the required personal protective equipment.
Remove the cap from the canister in which you prepared ConvoCare
rinse aid.
2.
■
Find the canister that is connected to the rinse aid connection (F)
with a (green) tube and that is located on the bottom left side of the
unit.
■
Unscrew the (green) supply tube (2), together with the wand, from
the canister you just identified.
■
Remove the empty rinse aid canister.
3.
■
Put the new, full canister (1) containing rinse aid in place.
■
Insert the (green) supply tube, together with the wand (2), into the
full canister (1) and screw it in place.
■
Make sure that the tube is routed without any kinks and that the vent
opening on the canister's cap is open and clear.
4.
■
Check to make sure that the canisters are set up correctly:
■
The canisters' supporting surface must not be higher than the
edge where the feet and the unit case meet.
■
The canisters' supporting surface must not be more than 3 feet
below this edge.
■
Check to make sure that the tube is connected to the right connec-
tion.
■
The rinse aid must go to unit connection F.
(indicated by a green color).
5 How to Clean the Combi Oven
Operating Manual
97