Meaning of parameters
Running times for washing stage 1 (pre-rinse 1)
P10 Water intake time
Setting range
Factory setting
( 0 = water intake by level)
0 - 900 sec.
0 sec.
P11 Drain valve delay
0 - 900 sec.
15 sec.
P12 Subsequent water intake period
0 - 900 sec.
240 sec.
P13 Suction time 1
0 - 900 sec.
60 sec.
P14 Suction time 2
0 - 900 sec.
0 sec.
P15 Final pumping (milk pump)
0 - 900 sec.
60 sec.
P16 Final suction time
0 - 900 sec.
30 sec.
P17 Pause
0 - 999 min.
0 min.
Running times for washing stage 2 (pre-rinse 2)
P20 Water intake time
Setting range
Factory setting
( 0 = water intake by level)
0 - 900 sec.
0 sec.
P21 Drain valve delay
0 - 900 sec.
15 sec.
P22 Subsequent water intake period
0 - 900 sec.
240 sec.
P23 Suction time 1
0 - 900 sec.
60 sec.
P24 Suction time 2
0 - 900 sec.
20 sec.
P25 Final pumping (milk pump)
0 - 900 sec.
60 sec.
P26 Final suction time
0 - 900 sec.
30 sec.
P27 Pause
0 - 999 min.
0 min.
Running times for washing stage 3 (main wash 1)
P30 Water intake time
Setting range
Factory setting
( 0 = water intake by level)
0 - 900 sec.
0 sec.
P31 Subsequent water intake period
0 - 900 sec.
150 sec.
P32 Circulation time
0 - 60 min.
5 min.
P33 Suction time 1
0 - 900 sec.
60 sec.
P34 Suction time 2
0 - 900 sec.
20 sec.
P35 Final pumping (milk pump)
0 - 900 sec.
60 sec.
P36 Final suction time
0 - 900 sec.
30 sec.
P37 Pause
0 - 999 min.
0 min.
Running times for washing stage 4 (intermediate rinse)
P40 water intake time
Setting range
Factory setting
( 0 = water intake by level)
0 - 900 sec.
0 sec.
P41 Suction time delay
0 - 900 sec.
15 sec.
P42 Subsequent water intake period
0 - 900 sec.
240 sec.
P43 Suction time 1
0 - 900 sec.
60 sec.
P44 Suction time 2
0 - 900 sec.
20 sec.
P-Parameters
Operation of the 'cleaning parameters, running times' level
Switch to level “cleaning parameters / running times”
!
See page 23.
WMS-100 104193 V2.7 - 14.10.2019
Working level
for normal daily operation
Code 471
Code 454
Code 382
Code 567
Page 25
Cleaning parameter
Configuration
(E-parameters)
Cleaning parameter
running times
(P-parameters)
Service parameters
(t-parameters)
User-defined
cleaning functions
(b-parameters)