WEKA_IOM_C-0068_TgxV_DN250_PN6_EN / 17.04.2020
32 / 38
6
Remove the compressed air line from the
actuator
Attention:
The actuator and the coupling are
moving parts. Risk of injury! Keep
your hands off.
7
Mount the coupling between actuator stem and
insert.
Tighten the two screws at the coupling with an
open-end spanner SW24
ATTENTION:
The insert must not be turned during
disassembly, this could result in irreversible
damage to the seat surface or to the actuator
diaphragm.
8
If a position controller is used:
Mount the plate in the coupling system and fix it
with the screws.
Do not tighten the screws.
Swivel back the position controller. Insert the
pin into the tappet.
Tighten the blue marked screws with an Allen-
type wrench, 5mm
Please note:
If the pin does not easily fit into the
tappet, the coupling has not been
aligned correctly.