WEKA_IOM_C-0068_TgxV_DN250_PN6_EN / 17.04.2020
18 / 38
Step
Picture
Description
Additional note: Depending on the nominal width of the valve, the components may slightly vary in
appearance. However, the steps remain the same.
1
If position controller is used:
Unscrew the blue marked screw with an Allen-
type wrench, 5mm
The plate can be removed together with the
spacer and bracket.
➔
The position controller (Tapper) are not
connected anymore
2
Remove the two screws at the coupling using
an open-end spanner SW24.
The coupling can be disassembled.
ATTENTION
The insert must not be turned
during disassembly, this could
result in irreversible damage to the
seat surface or to the actuator
diaphragm.