Troubleshooting suggestions
—
#ONTROL%RROR#ONDITION,OG
The Control is able to record information about the boiler’s condition at the time of the three previous faults or errors. This
information is available to view in Contractor Menus under “DIAGNOSTICS” by selecting “FAULT HISTORY” The control will
display the following information:
Information
Description
Action
Ignition Retries
Displays cumulative ignition attempts.
It is recommended that this be reset during yearly
maintenance.
Press and reset button to reset the count or select this
parameter and press enter to reset.
Manual Reset Count
Records number of lockouts that required a manual reset
since this count was last cleared.
Press the reset button to reset this count.
Auto Reset Count
Records number of lockouts that have automatically reset
since this count was last cleared.
Press the reset button to reset this count.
Lockout History 1- 6
Details of present or last recorded lockout, up to 6 previous
lockouts.
Select and press the right arrow key for more details.
How to read the last 6 lockout histories:
1.
1SFTTi%*"(/045*$4wCVUUPO
2.
4FMFDUi'"6-5)*4503:wBOEQSFTTUIFSJHIUBSSPX
LFZ
3.
4FMFDUi-0$,065)*4503:wBOEQSFTTUIF
right
BSSPXLFZ
4.
3FWJFXGBVMUJOGPSNBUJPOEJTQMBZFEPOTDSFFO
How to clear all lockout histories:
1.
8IJMFPOUIFi'"6-5)*4503:wTDSFFOIPMEUIF
SFTFUCVUUPOVOUJMDMFBSFE
RESTART WIZARD
The user must hold the button for a specified length of time.
Upon completion, this will erase user specific parameter
settings and take the user back through the wizard.
ONCE THIS IS CHOSEN, PREVIOUS SETTINGS
CANNOT BE RECOVERED. ENSURE THIS ACTION
IS TRULY DESIRED BEFORE CONTINUING.
RESET TO FACTORY DEFAULT
1. The user must hold the button for a specified length of
time. Upon completion, this will reset the control settings
back to factory installed settings.
ONCE THIS IS CHOSEN, PREVIOUS SETTINGS
CANNOT BE RECOVERED. ENSURE THIS ACTION
IS TRULY DESIRED BEFORE CONTINUING.
2. Reset to Factory Default can be found on the BOILER
SETTINGS menu, see Figure 80, page 87.
Troubleshooting
(continued)