上
海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
29
/
47
Example
In the figure below, the two shooting points are horizontal in X-axis direction with
40mm distance and the first shooting point is set as workpiece origin:
Thus, the position of the second point is (X40, Y0).
After setting, click
Template Edit
.
Outline Positioning
dialog box pops up. For
details, please refer to
Edit a Template
.
Shoot by Three Points
With this shooting method, the three points must form a right triangle. And when
programming, you need to set the center point of the hypotenuse as the workpiece
origin.
To shoot by three points, do the following:
1.
Switch to
Param
page and set the parameter
CCD Shoot Mode
to
3
.
2.
Move X-axis and Y-axis to the position of the first shooting point and click
Pick
Current
under
Mark 1
.
3.
Move X and Y axes to the position of the second shooting point and click
Pick
Current
under
Mark 2
.
4.
Move X and Y axes to the position of the third shooting point and click
Pick
Current
under
Mark 3
.
After setting, click
Template Edit
.
Outline Positioning
dialog box pops up. For
details, please refer to
Edit a Template
.