上
海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
22
/
47
After setting, exposure and gain time corresponding to the percentages
automatically shows.
Note:
Too large percentage of
Expose
results in low captured frame rate. Thus,
Expose
should be
set properly.
After setting
Expose
, you need to consider whether to increase the shoot delay
time(unit: ms).
In general, the requirement of shoot delay time is as the follows:
Shoot Delay Time
>
100ms + Exposure Time
Among them,
100ms
refer to the machine’s stop time.
Example
If
Expose
is set to
7%
, the corresponding exposure time is 0.035s (35ms). Thus, it is
reasonable to set the shoot delay time to 200ms.
4.2.
Debug CCD and the Machine
Focal length, magnification and offset are fixed after the machine tool is installed. If
the machine tool is replaced or repaired (e.g. the camera or lens is reinstalled), these
three values need to be re-measured. That is, debugging CCD and the machine tool is
required.
To debug CCD and the machine tool, do the following:
1.
Click
Basic Setting
→
Set
and check
Setting ON
.
2.
3.
4.
Measure the offset between the spindle and CCD
4.2.1.
Measure the Focal Length
Aim of the operation: Before shooting, X-axis and Y-axis move to the shooting point
and Z-axis moves to the focal height.
To measure the focal length, do the following:
1.
Manually move Z-axis until the camera can take a clear picture.
2.
Enable
X10
with handwheel to move Z-axis until Z-axis finds the clearest
position.