background image

Press  and   Hold for 2 seconds to power on or power off, after power on the 
indicator will  show “000000-999999”. After self inspection. It go to the weigh-
ing mode and 0.0 will be displayed on the unit.

Switching on/off the VS-2501

Battery Operation
Red Battery Light: Shows when battery is low
Green Battery light: Battery Charged

Battery Operation

Your VS-2501 is equipped with an internal rechargeable battery. The unit will automati-
cally switch to battery mode when the power supply is disconnected from the Indicator

When you use the VS-2501 for the fi rst time it is recommended to charge the battery for 
full eight hours

Press and Hold for 2 seconds to power the unit off.

Visit www.scaleman.com to purchase your WeighSouth VS2501

Visit www.balances.com to purchase your WeighSouth VS2501

Содержание VS-2501

Страница 1: ...VS 2501 Veterinary Scale Operations Manual Visit www scaleman com to purchase your WeighSouth VS2501 Visit www balances com to purchase your WeighSouth VS2501...

Страница 2: ...ith the scale The indicator is static and sensitive equipment Remove power during electrical servicing Internal components touched by hand will void warranty Handle the scale with care Do not put exce...

Страница 3: ...ully loaded scale Assembling 1 With the box opened you will notice the large platform upside down While in the box screw in the 4 adjustable feet into each corner of the base assembly Make sure that e...

Страница 4: ...Battery light Battery Charged Battery Operation Your VS 2501 is equipped with an internal rechargeable battery The unit will automati cally switch to battery mode when the power supply is disconnected...

Страница 5: ...es Tared Weight Values Gross Weight is shown Indicates a Tare value is stored Weighing unit is pounds Battery Indicates check weighing function Weight is Zero and Stable The weighing data is stable Gr...

Страница 6: ...zero 4 Place the actual weight including the tared container onto the platform The Weight displayed is the actual weight of the object not including the container 5 To remove Tare value press with no...

Страница 7: ...mal by placing the animal on the platform Once the animal becomes stable within tolerances the VS 2501 will calculate the average from various readings Once the average is set the VS 2501 will lock in...

Страница 8: ...with each C Function having different settings Entering Set Up Menu Press C01 Navigating Menu Structure 1 C Function C Sub Menu Enters C Function Exits C Sub Menu Exits and Saves C Functions Only Exc...

Страница 9: ...g menu C01 C39 step Method of operation display Remark 1 C01 After you enter calibration mode it display C01 2 press C01 1 Weight unit option 1 kg 2 lb 3 press press press or C02 C02 0 C02 2 Set decim...

Страница 10: ...lease choose 1 and ensure scale is empty and stable light is on Ensure zero calibration countdown Till show 0 00 example for two decimal point 7 press press press or press press or press C06 C06 0 C06...

Страница 11: ...ting Item parameters setting and instruction warning tone C08 warning tone Options 0 close warning tone 1 open warning tone Automatic power off C09 Automatic power off option 0 close auto power off 10...

Страница 12: ...2 1 kg lb conversion is ok C13 Upper limit alarm value Upper lower limit alarm C14 Lower limit alarm value You can set it within the max capacity limit Inner Code display C15 Check inner code enter C1...

Страница 13: ...pacity 10 10 max capacity 20 20 max capacity 100 100 max capacity Zero range C21 Initial zero range option 0 no initial zero setting 1 1 max capacity 2 1 max capacity 5 1 max capacity 10 1 max capacit...

Страница 14: ...ge 01d 99d remark d division Negative display C25 Negative display range Option 0 9d 10 10 max capacity 20 20 max capacity 50 50 max capacity 100 100 max capacity C26 Standstill time Option 0 quick 1...

Страница 15: ...er more stable if the loaded weight shake not too much The setting is less than 3 C29 Noise filter option 0 close noise filter 1 1 digital filter strength 2 2 digital filter strength 3 3 digital filte...

Страница 16: ...unication C35 C35 0 99 signal Gravity of calibration location C36 C36 9 7000 9 9999 Gravity of destination C37 C37 9 7000 9 9999 Version No C38 Preserved menu C39 Visit www scaleman com to purchase yo...

Страница 17: ...0 0 One Decimal Point 2 0 00 Two Decimal Point Scale Graduation C03 C03 1 0 0 1 0 1 2 0 2 5 0 5 Scale Maximum Capacity C04 0 Scale Zero Calibration C05 C05 0 0 No Zero Calibration 1 Zero Calibrate Sca...

Страница 18: ...put and output resistance ERR1 During calibration not input the weights or the weight is overload 1 Input the correct weights ERR2 During calibration the input signal is nega tive The calibration weig...

Страница 19: ...r replacement or credit at The Manufacturer option Any product repaired or replaced under the foregoing warranty shall be shipped back to customer freight and insurance prepaid Except as provided abov...

Отзывы: