Use setup mode if you have to change a setting or calibrate the
outputs. The setup mode stops all operation. As soon as you have
setup the last parameter, the unit behaves as if it has been switched on
with the new settings. This does not mean that the total is reset - you
must do this yourself if necessary.
If you want to abandon all the changes you have made, simply remove
the security link (or remove the power) before the
save
message is
shown.
To change the instrument setup:
1. Connect the security link (short pins 8 & 9).
. Press the
PGM
key.
The setup sequence is shown in the table on page two.
•Setupoptions
General
There are four basic areas of the instrument operation that must be
setup on a fully configured PTX800A. They are:
• Analogue Current/Voltage inputs;
• Display and keypad operation;
• Alarms one and two (optional); and
• Analogue outputs (optional).
You can disable the alarms and/or analogue outputs if you do not need
them (if so their settings will not be displayed).
Softwareversion
The information in this guide refers to versions 1.00 to 1.11.