9�4
Maintenance
Please note:
Subsequent mentions of descriptions and position numbers refer to
Chapter 3. Product overview / product description on page 11
Î
If you detect any leaks or malfunction, replace the WEH
®
Product or send it to WEH
for maintenance. Stop using the product immediately.
The following maintenance work may be carried out by the operator:
Î
Check the WEH
®
Product for leak tightness and correct functioning – ease of move-
ment, sufficant lubrication, wear, contamination and damage.
Î
Regularly check the clamping jaws for dirt accumulation. Dirt particles can interfere
with the clamping and sealing function, posing a potential hazard.
Î
Check the tightening torque of the grub screw (Pos. 5) at the V-actuation.
Tightening torque 0.5 Nm.
10. LUBRICATION
Please note:
Subsequent mentions of descriptions and position numbers refer to
Chapter 3. Product overview / product description on page 11
10�1
Safety instructions for lubrication
Î
Take care not to damage sealing surfaces or sealing components when lubricating.
Î
Only use WEH
®
Maintenance spraypart no. E99-44923 for lubrication.
10�2
Lubrication
Î
Apply a short burst of spray with the aiming tube to the
actuator peg (Pos. 3) (
).
Attention:
The lubricant must not be allowed to enter the
gas channel.
Figure 15
MD-10021-L51-R2.1.0-03
Page 24
Operating instructions
AE
Содержание TW156