Parameters Description
Crane | 34
3.7 CONFIGURATION OF THE LIMIT SWITCHES
3.7.1 Vertical
P1025 – Limit Switches Configuration
Adjustable
0 = Without Limit Switches
Factory Setting:
0
Range:
1 = Hoisting Slowdown via DI3
2 = Hoisting Slowdown via DI7
Proprieties:
CFG
Access groups via HMI:
SPLC
Description:
This parameter configures the manner an interlocking function of the Crane Vertical Motion applicative will be
associated to a digital input. This interlocking is no more than limit switches installed in the hoisting and lowering
travel course, which indicate operation conditions when activated.
■
Hoisting Slowdown (speed reduction): With an active hoisting command and activated sensor (logical level
“0”), it decelerates the motor down to the minimum speed defined at P0133 respecting the ramp defined at
P0101.
NOTE!
Refer to the section 3.8.1 for more information on the functions of the digital inputs, bearing in mind
that the parameters P1023 and P1025 operate together in the execution of the commands for the
crane vertical motion applicative.
3.7.2 Horizontal
P1025 – Limit Switches Configuration
Adjustable
0 = Without Limit Switches
Factory Setting:
0
Range:
1 = Forward Slowdown via DI7 and Reverse Slowdown via DI8
Proprieties:
CFG
Access groups via HMI:
SPLC
Description:
This parameter configures the manner an interlocking function of the Crane Horizontal Motion applicative will be
associated to a digital input. This interlocking is no more than limit switches installed in the forward and reverse
travel course, which indicate operation conditions when activated.
■
Forward Slowdown (speed reduction): With an active forward command and activated sensor (logical level
“0”), it decelerates the motor down to the minimum speed defined at P0133.
■
Reverse Slowdown (speed reduction): With an active reverse command and activated sensor (logical level
“0”), it decelerates the motor down to the minimum speed defined at P0133.
NOTE!
Refer to the section 3.8.2 for more information on the functions of the digital inputs, bearing in mind
that the parameters P1023 and P1025 operate together in the execution of the commands for the
crane horizontal motion applicative.