20
side burner iGnition
Summary lighting instructions are inside the left hand cabinet door .
m
dAnGer
failure to open the lid while igniting the side burner, or not
waiting five minutes to allow the gas to clear if the side
burner does not light, may result in an explosive flare-up
which can cause serious bodily injury or death.
off
stArt/hi
Low
SIDE bURNER IGNITIoN & USAGE
2
3
2
4
5
1
2
m
wArninG: Check hose before each use of barbecue for
nicks, cracking, abrasions or cuts. if the hose is found to
be damaged in any way, do not use the barbecue. replace
using only weber
®
authorized replacement hose. Contact
the Customer service representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
A) Open the side burner lid
(1) .
B) Check that the side burner valve is turned off
(2) (Push control knob in and turn
clockwise to ensure that it is in the OFF position), turn all burners not being used to
the OFF position (push in and turn clockwise) .
C) Turn the gas supply valve on
(3) .
D) Push down and turn the side burner control valve to START/HI
(4) .
E) Press the igniter button several times so it clicks each time until you see a flame
(5) .
m
CAution: side burner flame may be difficult to see on a
bright sunny day.
m
wArninG: if the side burner does not light in five seconds:
a) turn off the side burner control valve, main burners
and gas supply at source.
b) wait five minutes to let the gas clear before you try
again, or try lighting with a match (refer to “side
burner MAnuAL iGnition”).
◆
to eXtinGuish
Push down and turn side burner control knob to the OFF position . Be sure the burner is
off and cool before closing the side burner lid .
◆
the grill illustrated may
have slight differences
than the model purchased.