GAS INSTRUcTIoNS
refiLLinG the LiQuid ProPAne CYLinder
We recommend that you refill the LP cylinder before it is completely empty .
Removal of the LP cylinder:
A) Close cylinder valve (turn clockwise)
(1) .
B) Unscrew regulator coupling by turning counterclockwise, by hand only
(2) .
C) Loosen cylinder lock wing nut and turn cylinder lock up out of the way
(3) .
D) Lift cylinder off .
To fill, take the LP cylinder to a gas propane dealer, or look up “gas-propane” in the
phone book for other sources of LP gas .
m
wArninG: we recommend that your LP cylinder be filled
at an authorized LP gas dealer, by a qualified attendant,
who fills the cylinder by weight. iMProPer fiLLinG is
dAnGerous.
m
CAution: Place dust cap on cylinder valve outlet whenever
the cylinder is not in use. only install the type of dust cap
on the cylinder valve outlet that is provided with the cylinder
valve. other types of caps or plugs may result in leakage of
propane.
◆
Check
A) Regulator hose to bulkhead connection
(1) .
B) Main gas line to bulkhead connection
(2) .
C) Main gas line to manifold connections
(3) .
D) Side burner gas line to manifold connection
(4) .
E) Side burner pipe fitting to side burner cup
(5) .
F) Side burner pipe fitting to side burner valve connections
(6) .
m
wArninG: if there is a leak at connection (1, 2, 3, 4, 5, or 6),
re-tighten the fitting with a wrench and recheck for leaks
with soap and water solution. if a leak persists after re-
tightening the fitting, turn off the gas. do not oPerAte
the GriLL. Contact the Customer service representative in
your area using the contact information on our web site.
Log onto www.weber.com
®
.
G) Side burner quick disconnect connection
(7) .
H) Regulator hose to cylinder connection
(8) .
I) Regulator hose to regulator connection
(9) .
J) Valves to manifold connections
(10) .
m
wArninG: if there is a leak at connections (7, 8, 9 or 10),
turn off the gas. do not oPerAte the GriLL. Contact
the Customer service representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water .
reinstall Control Panel
You will need: Phillips screwdriver .
A) Position top edge of control panel on tabs of frame . Push down into position .
B) Reinstall igniter module .
C) Slide both shorter wind deflector tabs toward inside edge of control panel while you
slide longer tab over outside edge . Seek previous illustrations for reference .
D) Line up screws with screw holes on both control panel bracket and frame .
E) Tighten screws .
F) Place corresponding control knobs onto valve stems .
◆
1
2
3
the grill illustrated
may have slight
differences than the
model purchased.