GRANUDOS S5, control unit
Index: 02
Date modified: 11/05/2021
OI No.: BA SW 014-02 Granudos S5-Steuereinheit EN.docx
Page 27 of 29
Operation data sheet,
--master copy--
Please copy the blank operation data sheet before filling it out!
Settings menu
Ex works setting Setting ranges
Step during commissioning Optimised during op-
eration
1.
Chlorine/pH dosing
performance
Date:
Date:
Chlorine
15 seconds
1-15 seconds
1
pH (acid)
8 seconds
1-8 seconds
1
Cycle
30 seconds
30-360 seconds
30
Dosing time limit acid
0
0-100 minutes
5
Dosing time limit chlorine 0
0-100 minutes
5
2.
Shock chlorination
Chlorine dosing perfor-
mance
50 %
depending on the
technical configura-
tion
1
Acid dosing performance 50 %
depending on the
technical configura-
tion
1
3.
System
Password
Technician
0123
0000 – 9999
1
4.
Dust extraction
Run-on
0
0 - 60 seconds
Flushing time
5 seconds
1 - 5 seconds
1
Flushing interval
0 h
0 – 48h
1
5.
Delay booster pump
Delay time
120 seconds
0 - 120 sec
5
6.
Configuration chlorine
Rotation speed dosing
screw
depending on de-
sign
12 – 60 rpm
1
Diameter dosing screw
depending on de-
sign
19 / 26mm
1
7.
Configuration pH
Hose diameter
depending on de-
sign
0.8/1.6/3.2/4.8/ext
8.
Control
Control
PWM
PWM, freq., manual
9.
Invert the inputs
CCT OFF
NO
NO/NC
Dos CCT OFF
NO
NO/NC