9.3
Commissioning protocol
The commissioning protocol can be found in the operating instructions for the dosing unit of the respective
dosing device in
Chapter
:
for Granudos 10-S5 + 15-S5,
No.: BA SW 002
for Granudos 45/100-S5,
No.: BA SW 003
9.4
Operation data sheet
During a
“software update”
, all parameters are reset to the ex-works setting. After an “update”, all parameters
must therefore be checked and readjusted to the pool. We therefore recommend that you enter the
optimised, pool-specific parameters in this list.
Settings menu
Ex works setting Setting ranges
Step during commissioning
Optimised
during
operation
1.
Chlorine/pH dosing
performance
Date:
Date:
Chlorine
15 seconds
1-15 seconds
1
pH (acid)
8 seconds
1-8 seconds
1
Cycle
30 seconds
30-360 seconds
30
Dosing time limit acid
0
0-100 minutes
5
Dosing time limit chlorine 0
0-100 minutes
5
2.
Shock chlorination
Chlorine dosing
performance
50 %
depending on the
technical
configuration
1
Acid dosing performance 50 %
depending on the
technical
configuration
1
3.
System
Password
Technician
0123
0000 – 9999
1
4.
Dust extraction
Run-on
0
0 – 60
Flushing time
5 seconds
1 - 5 seconds
1
Flushing interval
0 h
0 – 48h
1
5.
Delay booster pump
Delay time
120 seconds
0 - 120 sec
5
6.
Configuration chlorine
Rotation speed dosing
screw
depending on
design
12 – 60 rpm
1
Diameter dosing screw
depending on
design
19 / 26mm
1
7.
Configuration pH
Hose diameter
depending on
design
0.8/1.6/3.2/4.8/ext
8.
Control
Control
PWM
PWM, freq., manual
9.
Invert the inputs
CCT OFF
NO
NO/NC
Dos CCT OFF
NO
NO/NC