Fragrance Dosing, Type DUFTDOS-DS
Index: 01
Date modified: 20.09.2017
BA no.: BA DW 015-01 Duftdos-DS EN 14168-21659.docx
Page 20 of 28
7.1.3
Test pump functioning
Set the pause time to "0". The retaining washer must revolve.
Test pump suction function
1.
Pull pump suction hose out of the container.
2.
The pump must suck in air, which causes air bubbles in the dosing line.
If no air is being sucked in, the suction function is faulty.
3.
The dosing line must then be vented.
See Section 5 "Commissioning".
Trouble-shooting
CAUTION!
Fragrance concentrates may be harmful to health!
Wear protective gloves and goggles when working on the suction or dosing line.
Fault table
Fault
Possible cause
Measures
The device cannot be switched on
Power plug not connected
Power supply interrupted
Steam generator deactivated (if
connected to steam generator)
Insert power plug
Check power supply
Activate steam generator
Device not functioning
Control board jumpers incorrectly
set
Control circuit board defective
Check settings
Renew control board
Dosing pump not functioning
Pump motor faulty
Check / renew pump motor
No fragrance dosing
•
Fragrance concentrate
container
empty
•
Air in the dosing line
•
Fragrance pump faulty
•
Dosing pump hose faulty
•
Roller support worn-out
•
Dosing valve blocked
•
Fragrance concentrate
contaminated
•
Refill container
•
Vent dosing line
with fragrance pump
•
Check pump / renew
•
Renew hose
•
Renew roller support
•
Check / clean / renew dosing valve
•
Carry out a visual inspection of the
fragrance concentrate for clarity and
cleanliness. Renew contaminated
concentrate