5.2.3
Insert roller support for hose pump
1.
Remove clip-on transparent protective cover (5, not depicted).
2.
Remove blue retaining washer (2).
3.
Remove hose bracket (15) from pump casing.
Figure 6, Hose Pump
Key
11 Pump casing
12 Retaining washer
13 Pressure connection
14 Suction connection
15 Hose bracket with dosing hose made
from viton (hose set)
16 Hose
17 Roller support (covered by retaining
washer)
-
Transparent protective cover (not
depicted)
4.
Place yellow roller support (17) on the shaft.
5.
Insert hose bracket (15) into the casing guide until it locks in completely.
6.
Turn roller support (17) anti-clockwise and press the hose carefully into
the casing until the hose sits completely in the casing.
Renew the retaining washer (12).
Reattach the transparent protective cover. The roller support is now fully
installed.
The roller support and hose bracket are disassembled in the reverse order.
Figure 7,
Insert roller support
Figure 8,
Insert hose bracket
Figure 9,
Turn roller support
12
11
13
14
15
16
17