background image

Operating Instructions and Parts Manual

3

WLS Series

www.waynepumps.com

(A) SPRING:

A spring that emerges 

from the ground. 

Occurs when water in 

permeable materials is 

trapped between 

impermeable

material as rock or clay

.

(B) LAKE, STREAM or POND:

Surface water

, unless treated,

is usually not safe for human

consumption. It may be used

for purposes such as washing

or irrigation.

(C) DUG WELL:

A hole is excavated

several feet in diameter

to a fairly shallow 

depth. It is then lined

with brick, stone or

concrete to prevent

cave-in.

(D) DRIVEN WELL:

Pipe with a pointed

screen is driven into

the ground below 

the water table. 

The depth is usually

less than 50 feet. 

A

vailable 

diameters are 

1" through 2".

(E) DRILLED WELL:

A hole bored into the 

earth with machinery and

lined with pipe. Depths 

range from a few feet 

to over 1000 feet.

Common well diameters 

are 2", 3", 4" and 6" for

domestic water wells.

(F) CISTERN:

An underground tank 

built to collect rain 

water from rooftops.

The water is not fit

for human consumption.

(A) SPRING

(B) LAKE, 

STREAM, POND

(C) DUG WELL

(D) DRIVEN WELL

(E) DRILLED WELL

(F) CISTERN

SHALE

TOP SOIL

CLA

Y

PERMEABLE

MA

TERIAL

W

A

TER

BEARING

SAND

W

A

TER T

ABLE

W

at

er

 S

o

ur

ce

s D

ia

g

ra

m

Содержание WLS150

Страница 1: ...10 ft 15 ft 20 ft 25 ft WLS150 15 Gal hr 4350 4200 3950 3700 3500 20 Gal hr 3950 3700 3450 3250 3050 25 Gal hr 3400 3200 3000 2800 2500 30 Gal hr 2950 2750 2500 2150 1700 WLS200 15 Gal hr 5300 5150 4...

Страница 2: ...se damage to equipment This is the safety alert symbol It is used to alert you to potential bodily injury hazards Obey all safety messages that follow this symbol to avoid possible harm NOTE Informati...

Страница 3: ...k stone or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through...

Страница 4: ...nchement incorrect du moteur d une temp rature ambiante excessive sup rieure 100 F 38 C d une ventilation inad quate ou d une pompe ou d un moteur d fectueux INSTALLATION Protect pump from the element...

Страница 5: ...nts or couplings will allow air to leak into the pipe and cause poor pump operation or difficulty priming Make sure to use pipe joint compound or plumber s seal tape on all threaded pipe connections L...

Страница 6: ...and installation instructions DUG WELL CISTERN LAKE AND SPRING INSTALLATION Install a foot valve on the inlet pipe and lower into the water Locate foot valve no closer than 2 feet from the bottom of t...

Страница 7: ...lector WLS150 Only CONNECTING WIRES Terminal cover must be in place for safe operation Ground in accordance with local and national electrical codes Keep fingers and objects away from openings and rot...

Страница 8: ...take on the diffuser has an O Ring seal and is covered with a lubricant remove the O Ring and discard 7 Remove the black end cap from the back of the motor exposing the motor shaft end on the WLS200 y...

Страница 9: ...but no water is delivered NOTE Check to make sure the pump is properly primed before looking for other causes Unscrew priming plug and see if water is in priming hole 1 Pump in new installation did n...

Страница 10: ...description and number as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A REPLACEMENT PARTS LIST Ref No Description Part Number Qt...

Страница 11: ...IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE...

Страница 12: ...NOTES 12 www waynepumps com...

Отзывы: