background image

Operating Instructions and  Parts Manual

4

www.waynepumps.com

GENERAL SAFETY INFORMATION (CONT’D)

  All wiring must be performed by a qualified 

electrician. The pump must be installed in compliance with 

all local and national codes.

  L’ensemble du câblage doit être 

effectué par un électricien qualifié. La pompe doit être 

installée en conformité avec toutes les lois locales et le Code national 

de l’électricité.

2.  Connect this product to a grounded circuit equipped with a ground 

fault circuit interruptor (GFCI) device.

3.  Before installing this product, have the electrical circuit checked by 

an electrician to ensure proper grounding.

4.  Be certain the pump power source is disconnected 

before installing, servicing, or maintaining the pump.

5.  Check motor voltage setting on motor end plate and 

make sure the line voltage of the electrical current 
supply is correct (see figure 5 on page 7).

6.  Be sure the water source and piping is clear of sand, dirt and scale. 

Debris will clog pump and will void warranty.

7.  Failure to protect pump and piping from freezing could cause severe 

pump and/or property damage and will void the warranty.

8.  Do not run pump dry. Follow priming instructions (see Page 8).

  Pump motor is equipped with an automatic 

resetting thermal protector and may restart unexpectedly. Protector 

tripping is an indication of motor overheating because of operating 

pump at low heads (low discharge restriction), excessively high or low 

voltage, inadequate wiring, incorrect motor connections, excessive 

surrounding air temperature (greater than 100° F), inadequate 

ventilation, and/or defective motor or pump.

  Le moteur de la pompe est doté d’un protecteur 

thermique à réinitialisation automatique et pourrait redémarrer 

de manière imprévue. Le déclenchement du protecteur est une 

indication de surchauffe du moteur à cause d’une utilisation de la 

pompe à faible hauteur de chute (restriction de faible décharge), 

d’une tension excessivement haute ou basse, d’un câblage inadéquat, 

d’un branchement incorrect du moteur, d’une température ambiante 

excessive (supérieure à 100° F - 38° C), d’une ventilation inadéquate ou 

d’une pompe ou d’un moteur défectueux.

INSTALLATION

  Protect pump from the elements by installing 

in a basement, garage, tool shed or pump house. Install the pump so 

the center of the pump is as close as possible to the water level. Keep 

installation area clear to provide access for service and maintenance. 

Protect the pump against flooding and excess moisture. Failure to do so 

will void warranty.

Water Sources (See Diagram on Page 3)

Drilled Well, Driven Well, Dug Well, Cistern, Lake and Springs.

PUMP PIPING INSTALLATION

Use new pipe for best results. Galvanized metal or solid plastic must be 
used. When using galvanized pipe, provide independent supports for 
both suction and discharge piping near the pump to avoid strain on the 
pump. Minimize use of elbows and fittings to reduce friction loss. Refer to 
the friction loss chart (below) for specific information.
Increase diameter of suction or discharge piping if length is over 50 feet.

SUCTION PIPING

  Install foot valve or strainer screen over intake 

of suction piping.

  Installer un clapet de pied ou un tamis sur 

l’entrée de la tuyauterie d’aspiration.

Never use pipe smaller than 2” in diameter for suction piping. The suction 
pipe must be kept free of air leaks. For horizontal runs, lay pipe from the 
water source so the upward slope is at least 1/4” per foot. This eliminates 
trapped air. The threaded inlet of the pump is 2” NPT.

  Do not install suction piping near swimming 

areas.

  Ne pas installer la tuyauterie d’aspiration près 

des zones de baignade.

DISCHARGE PIPING

Install a 1-1/2” pipe tee in the pump discharge to allow easy priming. 
Plug the end of the tee opposite the pump to allow the branch piping to 
go to the spray nozzles (See Figure 1). Remove the pipe plug to fill the 
pump with water for priming (See Priming Instructions on Page 6). 

Pipe Size 

(inches)

PSI Friction Loss in 100 Feet of Pipe

US Gallons per Hour

1200

1500

1800

2400

3000

3600

4800

6000

7200

1.25

2.6

3.9

5.5

9.4

14.1

22.0

1.5

1.2

1.9

2.6

4.4

6.7

9.4

17.5

2.0

0.6

0.8

1.3

2.0

2.8

4.7

7.1

10.0

2.5

0.6

0.8

1.2

2.0

3.1

4.3

Содержание WLS150

Страница 1: ...10 ft 15 ft 20 ft 25 ft WLS150 15 Gal hr 4350 4200 3950 3700 3500 20 Gal hr 3950 3700 3450 3250 3050 25 Gal hr 3400 3200 3000 2800 2500 30 Gal hr 2950 2750 2500 2150 1700 WLS200 15 Gal hr 5300 5150 4...

Страница 2: ...se damage to equipment This is the safety alert symbol It is used to alert you to potential bodily injury hazards Obey all safety messages that follow this symbol to avoid possible harm NOTE Informati...

Страница 3: ...k stone or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through...

Страница 4: ...nchement incorrect du moteur d une temp rature ambiante excessive sup rieure 100 F 38 C d une ventilation inad quate ou d une pompe ou d un moteur d fectueux INSTALLATION Protect pump from the element...

Страница 5: ...nts or couplings will allow air to leak into the pipe and cause poor pump operation or difficulty priming Make sure to use pipe joint compound or plumber s seal tape on all threaded pipe connections L...

Страница 6: ...and installation instructions DUG WELL CISTERN LAKE AND SPRING INSTALLATION Install a foot valve on the inlet pipe and lower into the water Locate foot valve no closer than 2 feet from the bottom of t...

Страница 7: ...lector WLS150 Only CONNECTING WIRES Terminal cover must be in place for safe operation Ground in accordance with local and national electrical codes Keep fingers and objects away from openings and rot...

Страница 8: ...take on the diffuser has an O Ring seal and is covered with a lubricant remove the O Ring and discard 7 Remove the black end cap from the back of the motor exposing the motor shaft end on the WLS200 y...

Страница 9: ...but no water is delivered NOTE Check to make sure the pump is properly primed before looking for other causes Unscrew priming plug and see if water is in priming hole 1 Pump in new installation did n...

Страница 10: ...description and number as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A REPLACEMENT PARTS LIST Ref No Description Part Number Qt...

Страница 11: ...IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE...

Страница 12: ...NOTES 12 www waynepumps com...

Отзывы: