background image

Limited Warranty

 

 

W

ayne Dalton, a division o

f Overhead Door Corpora

tion, (“Seller”) warrants to the original pur

chaser o

f the Models 800F 

and 800FE commer

cial r

olling steel door (“

Door”) and Genie GCL

-MH
, MJ

, J

, H
, or GH commer

cial opera

tor (“

Opera

tor”) 

(Door and Opera

tor pur

chased and installed together collectively r

ef

err
ed to as the “S

ystem”), subject to all o

f the terms 

and conditions her

eo
f, tha

t the S

ystem ther

eo
f will be fr

ee fr

om def

ects in ma

terials and workmanship under normal use 

for the f

ollowing period(s) o

f time, measur

ed fr

om the da

te o

f installa

tion:

Seller warrants all parts and components of the System, ex

cept the counterbalance spring and finish, to be free from 

defects in ma

terials and workmanship for Three (3) Y

ears from the da

te of installa

tion or 10

,000 cycles

1

, whichever 

occurs first.

Seller’s obliga

tion under this warranty is specifically limited to r

epairing or r

eplacing, a

t its option, any part which is de

-

termined by Seller to be def

ective during the applicable warranty period. Repair or r

eplacement labor f

or any def

ective 

System component is ex

cluded and will be the r

esponsibility o

f the pur

chaser

.

This warranty is made to the original pur

chaser o

f the S

ystem only and is not transf

erable or assignable. This Pr

oduct is 

intended f

or commer

cial and industrial applica

tions only

. Use in a non-

appr

oved applica

tion will void this warranty

. This 

warranty does not apply to any unauthoriz

ed altera

tion or r

epair o

f the S

ystem, or to any S

ystem or component which 

has been damaged or deteriora

ted due to misuse, neglect, accident, failur

e to pr

ovide necessary maintenance, normal 

wear and tear

, or acts o

f God or any other cause beyond the r

easonable contr

ol o

f Seller

. This warranty does not cover 

replacement ba

tteries or apply to any damage or deteriora

tion caused by door sla

ts rubbing together as the door r

olls up 

upon itself or caused by exposur

e to salt wa

ter
, chemical fumes or other corr

osive or aggr

essive envir

onments, whether 

na

turally occurring or man-made, including, but not limited to, envir

onments with a high degr

ee o

f humidity

, sand, dirt 

or gr

ease. This warranty applies only to S

ystems (a Door and Opera

tor pur

chased and installed together simultaneously) 

and not to any Door or Opera

tor pur

chased independently fr

om the other

, r

egar

dless o

f whether subsequently pair

ed 

together

.

THIS W

ARRANT

Y IS EX

CL
USIVE AND IN LIEU OF ANY O

THER W

ARRANTIES

, EITHER EXPRESS OR IMPLIED

, INCL

UDING 

BUT NO

T LIMITED T

O ANY IMPLIED W

ARRANT

Y OF MERCHANT

ABILIT

Y OR FITNESS FOR A P

ARTICULAR PURPOSE.

IN NO EVENT SHALL SELLER BE RESPONSIBLE FOR, OR LIABLE T

O ANY

ONE FOR, SPE

CIAL, INDIRE

CT
, C
OLLA

TERAL,

 

PUNITIVE, INCIDENT

AL OR C

ONSE

QUENTIAL D

AMA

GES

, even if Seller has been advised o

f the possibility o

f such 

damages. Such ex

cluded damages include, but ar

e not limited to, loss o

f goodwill, loss o

f pr
o

fits, loss o

f use, cost o

f any 

substitute pr

oduct, interruption o

f business, or other similar indir

ect financial loss.

Claims under this warranty must be made pr

omptly a

fter discovery

, within the applicable warranty period, and in writing 

to the Seller or to the authoriz

ed distributor or installer whose name and addr

ess appear below

. The pur

chaser must 

allow Seller a r

easonable opportunity to inspect any S

ystem claimed to be def

ective prior to r

emoval or any altera

tion o

its condition. Pr

oo
f o
f the pur

chase and/or installa

tion da

te, and identifica

tion as the original pur

chaser

, may be r

equir

ed. 

This W

arranty is not valid unless the fields below ar

e completed by the installer a

t the time o

f installa

tion.

1The number o

f cycles r

eferr

ed to her

ein shall be measur

ed by an in

tegra

ted cycle coun

ter con

tained in or a

ttached to the

 

Opera

tor
. If the cycle coun

ter is r

ender

ed inoperable, Seller shall use o

ther r

easonable means to determine the cycle coun

t.

Door T

ype: 

—————————————————————————————————————————————

Opera

tor T

ype: 

———————————————————————————————————————————

Customer Name (Original Pur

chaser): 

——————————————————————————————————

Customer Installa

tion Loca

tion: 

————————————————————————————————————

Or
der # 

———————————

 Da
te o

f Installa

tion: 

——————————————————————————

Name o

f Dealer/Installer: 

———————————————————————————————————————

Signa

tur
e o
f Dealer/Installer: 

—————————————————————————————————————

Rev
. 11.2022

W999-1047

R

olling Steel Models 

800

F and 

800

FE
 

Door and Opera

tor System

Limited W

arranty

Содержание 800F

Страница 1: ...on Anchor Requirement 500460 0001 Commercial Operator Installation Manual 111837 502351 Installation Instructions for FACE MOUNTED ROLLING STEEL STORM SHELTER DOOR with NON TENSION RELEASE AUTOMATIC C...

Страница 2: ...s a hazardous situation that if not avoided could result in minor or moderate injury The word NOTE is used to indicate important steps to be followed or important considerations POTENTIAL HAZARD EFFEC...

Страница 3: ...ges 22 23 Stop Pin RHX OPERATOR 1 Read manual and warnings carefully 2 Keep the door in good working condition 3 Keep instructions in a prominent location near the door system Key Drawing Safety Infor...

Страница 4: ...ation 4 Your DATA SHEET is shown below It is found inside the door hardware box You will need to refer to the data on this sheet during installation Verify that the Factory Order Number on the door co...

Страница 5: ...for the jambs Compare the guide type shown on the DATA SHEET with Figure 2 Can the guides be installed plumb Measure the length of the guide jamb angle and the height of the jamb opening The differen...

Страница 6: ...the DATA SHEET Both guides MUST be on a level line and both guides MUST be plumb The S dimension must be held within 1 8 over the entire height of guides Guide assemblies are designed to rest on floor...

Страница 7: ...all all jamb fasteners on one guide Recheck S distance and continue with installation NOTE When steel jamb does not extend above the opening use three thru bolts to fasten each wall angle above the op...

Страница 8: ...aft SPRING CONFIGURATION See Figure 7 Left hand drive counterbalance has end of spring pinned to barrel near tension end Right hand drive counterbalance has end of spring pinned to barrel several feet...

Страница 9: ...is 11 in diameter or larger slide set collar next to Tension Wheel and secure to tension shaft as shown in Figure 9 NOTE Tension wheel must remain free of spring tension until instructed to apply tens...

Страница 10: ...he inside of the headplate brackets See Figure 13 Brackets may have 2 or 3 mounting slots Put flat steel washer under bolt head and under nut Headplate brackets must be square to the wall and parallel...

Страница 11: ...head Door Corporation 11 8 OPERATOR MOUNTING OPTIONS For Additional Installation Details Refer To Provided Operator Installation Manual 111837 502351 Operator Install Mounting Options Top Of Hood Benc...

Страница 12: ...he top slat will have slots to attach to barrel Hook curtain over studs and fasten with 5 16 round head screws and washers and TWO clamp washers provided See Figure 19 Coil curtain completely onto bar...

Страница 13: ...w entrance to both LH and RH guides as shown in Figure 23 13 LOWER CURTAIN INTO GUIDES The next step is to lower curtain into guides but before loosening the ropes which holds the coiled curtain enoug...

Страница 14: ...ops and place a clamp on each guide no more than 6 below the bottom bar Make certain that the clamping force will be sufficient to stop the door when it rests on the clamps Carefully lower the curtain...

Страница 15: ...placed The hood may need to be loosened or removed for the application of the shim To apply the shim two laborers might be required Installing the shim D Close the door fully E When door is at bottom...

Страница 16: ...se and smoke detectors form C relay outputs notification appliance and troubleshooting capabilities The fail safe design incorp rates an annual internal clock calendar which generates a test trouble s...

Страница 17: ...ated doors are provided without a hand chain keeper provided with rolling service doors For safety reasons the hand chain may be held out of the opening by a wire loop fastened to a wall with the hand...

Страница 18: ...each side of the curtain are not rubbing on the headplate brackets Operate the door several times in order to make this determination Verify that the bottom bar is level in full down and full up posi...

Страница 19: ...2023 Wayne Dalton a division of Overhead Door Corporation 19 Final Door Install continued 24 HAND CHAIN KEEPER The emergency hand chain for this door can be locked Instruct door users to wrap hand ch...

Страница 20: ...tain from between the guide angles Lower the curtain and bottom bar outside the guides to a working position above the floor Remove one windlock so the damaged bottom bar and damaged slats can be remo...

Страница 21: ...el Check and replace Check and level barrel Door sticks when closing Bent guide angle s Inspect for bent or kinked guides Straighten guides and check width of groove Door coil makes cracking sound Ben...

Страница 22: ...r walk under moving door 3 Keep doorwa y clear and in full view while operatin g door 4 Do NOT permit children to play on near or with door or to operate controls 5 Unlock door before opening door 6 S...

Страница 23: ...he Nameplate Attached to your Bottom Bar 12 13 15 Hood Assembly not shown 307582 Inquire Inquire Inquire Yes Hood Logo Service Doors not shown OPTIONAL ACCESSORIES Built to Order parts are specific to...

Страница 24: ...empt will be made to correct the malfunction to the installed product in the field To return a defective part the authorized Wayne Dalton Distributor must contact the Wayne Dalton Tech Support Line 80...

Страница 25: ...sive or aggressive environments whether naturally occurring or man made including but not limited to environments with a high degree of humidity sand dirt or grease This warranty applies only to Syste...

Отзывы: