Internal Jumper Locations and Settings
While all Wāvtech models provide external controls for main adjustments, there are also a few internal
configuration jumpers available to resolve certain special vehicle or system conditions. The link6’s
internal jumper locations and default settings are shown in the illustration below. To access these
jumpers, simply remove the two top screws from each end panel and loosen two bottom screws on one
side in order to easily remove the chassis top cover. It is recommended to detach the power supply
connector first to ensure that the unit is completely powered off while making any jumper changes.
Notes:
Ÿ
Input sensitivity range jumpers (20V/40V) are independent for each SPK input channel, so may be set
differently between channels as system conditions require.
Ÿ
Load bypass jumpers (LOAD) are independent for each SPK input channel and must be removed or
moved to a single pin in order to disconnect the internal loading from that channel.
Ÿ
AUX input balanced-unbalanced jumper (BAL/UNBAL) affects both left and right channels.
8