81
Wavin AS+
Technical Manual
ANNEX II
Wavin AS+, low noise Soil & Waste
specification clauses
CONTENTS LIST
1000 Application
2000 Supplier
3000 Materials
4000 Performance Objectives
5000 Installation
6000 Documents to be provided to client
WAVIN AS+, LOW NOISE SOIL & WASTE SYSTEM
1000 Application
• Soil and waste system
2000 Supplier
• Wavin
3000 Materials
• Pipe
Material:
Mineral filled PP, density ~1,9 kg/dm³
Colour:
Grey RAL 7035
Stiffness:
> 4 kN/m²
• Fittings:
Material:
Mineral filled PP, density ~1,9 kg/dm³
Colour:
Grey RAL 7035
Seal:
SBR rubber
• Outer diameters (mm)
50; 70; 90; 100; 125; 150
4000 Perfromances Objectives
• Noise barrier properties according to
EN 14366 (Fraunhofer test P-BA 63/2019)
2 l/s WAVIN low noise bracket rubber lined metal braket
• Air borne:
48 dB(A)
• Structure borne:
12 dB(A)
• Temperature resistance:
The pipe system needs to be resistant against continuous
temperatures of 90°C and peak temperatures of 95°
5000 Installation
• According to WAVIN AS+ Installation manual
• Bracket fixing instruction:
Use full encircling metal brackets with rubber inserts.
Please use for correct installation the AS+ manual chapter 5 installation
6000 Documents to be provided to the client
Sound level: The contractor needs to demonstrate via an independent programme that the sound level in the rooms shall not exceed
the required sound levels. Unless stated otherwise the maximum sound level is: 30 dB(A). Explanation: the sound level is dependent
on amongst others the material of the pipe system, the wall thicknesses of the pipe and fittings, the diameter of the system, the
flow capacity, the duct material and construction, the type of brackets and mass of the fixation wall and room size. When one of
the variables changes, the calculation needs to be repeated with the new input values.