![Wavetronix Click 65 Series Скачать руководство пользователя страница 35](http://html2.mh-extra.com/html/wavetronix/click-65-series/click-65-series_user-manual_3892207035.webp)
34
CHAPTER 4
•
WEB INTERFACE
Verification Tab
Figure 4.6 – Verification Tab
The Verification tab allows users to check the current detection mappings using real-time
data coming from the sensors. The Channel Verification box contains a 4x4 grid that dis-
plays all 16 possible detection channels for the selected BIU.
Within the grid, a detector channel that does not have a mapping will be displayed with a
white circle. Detector channels with a current mapping will be displayed with a gray circle
(if the detector signal is currently inactive) or a red circle (if the detector signal is currently
active). The Verification tab will be updated in real time, so users will see the channel activa-
tions trigger on and off as vehicle detections are made by the attached sensors.
Click on a detection circle to display the current sensor channel mapping below the grid.
The text displayed to identify each sensor can be adjusted by selecting an option from the
Display…
drop-down box. The details box will also contain the phase mapping and de-
scription field (if any). Detector channels with multiple sensor channels assigned will dis-
play the details for each.
If a mapping exists, but the Click 65x is unable to communicate with the registered sensor,
the interface will display a red circle with a large “X”, indicating non-functional status.