CHAPTER 4
• WEB INTERFACE
27
field requires a number between 0 and 255.
•
Subnet Mask –
The registered subnet mask for the local network. Each numerical field
requires a number between 0 and 255.
•
Default Gateway –
The gateway IP address for the local network. Each numerical field
requires a number between 0 and 255.
•
Enable BIU –
These checkboxes can activate or deactivate any of the eligible BIU (Bus
Interface Units) within the Click 65x configuration.
Note
BIU IDs need to be unique across all cabinet devices communicating to the controller.
It’s recommended that you disable unused BIU IDs within the Click 65x so that other
cabinet devices may have access to that ID without communication conflicts.
•
Enable Sensor Data Port –
These checkboxes activate or deactivate the respective sen-
sor port for communication. Ports with a sensor attached need to be activated before
sensor events will be transmitted by the Click 65x. Ports without a sensor attached can
remain deactivated.
Push the
Save
button to save any modifications to these fields.
Note
Since the web interface URL uses the device IP address, if the IP address is changed,
the web interface will automatically redirect to use the new IP address, allowing the
user to continue using the web interface uninterrupted. Depending on the browser
type, this redirection may trigger a dialog box asking for user approval beforehand.