background image

4 of 14

WX-501-0537 • 01.22

Operating Modes

The Click 512 has three operating modes: 

Run

Device Setup

, and 

Serial Convert

. These modes are accessed through 

the mode menu, which is controlled via the push-button; the system (multicolored) LEDs light up to show which mode 

you’re currently on. The table below shows the LED color and state associated with each operating mode or task.

Operating Mode/Task

Selection LED State

Operating LED State

Run

Blue solid

Blue solid

Device Setup

Green solid

Green solid

Serial Convert

Yellow solid

Yellow solid

Reset

Red solid

The LED state during the mode selection process can be either flashing or solid. If the current mode is a flashing 

mode, the corresponding LED will flash during mode selection. However, after a flashing mode is selected, the 

selected mode LED will not flash—the red LED will flash instead. 

Navigating the Menu via the Push-Button

The menu is navigated via the push-button using hold and press actions:

 

Hold –

 Pressing and then holding for at least 1½ seconds allows you to enter the Click 512 mode selection process.

 

Press –

 Pressing and then quickly releasing the push-button allows you to make a selection in the menu.

The menu is used to select and run an application’s operating modes. Select a mode by navigating through the 

main menu (multicolored LEDs) and the submenus (yellow and red LEDs) as described below:
1.  Enter the main menu by holding the push-button down. Continue holding the push-button to cycle through the 

entire menu.

2.  Release the push-button once the cycle reaches the desired mode (see Table 9.1). 
3.  Press the push-button again to select the mode. Once the mode is selected it will start running. If you selected 

to reset the device, the submenu of yellow LEDs will start (the first LED will light up).

4.  Hold the push-button to cycle through the options of the submenu.
5.  Release the push-button once the desired option is displayed.
6.  Press the push-button again to select the option. The mode will now start running.

Run Mode (blue solid)

Run mode is the first mode presented in the mode selection process. Once you have configured the device using 

Click Supervisor (see the Device Setup Mode section below), use the push-button to select Run mode (blue solid).

Note. 

The SmartSensor HD should be configured beforehand, using SmartSensor Manager HD (SSMHD), to push 

event data (see the image below and the 

SmartSensor HD User Guide

 for more information).

Содержание Click 512

Страница 1: ...s met an alert will trigger through the contact closure and an ASCII string will be transmitted through the DB 9 port A possible application for the Click 512 is to warn specific drivers of a potentia...

Страница 2: ...pin 4 from the serial cable to prevent the device from going into Program mode If it enters Program mode all of the faceplate LEDs will turn off and you ll need to power cycle the device The other tw...

Страница 3: ...e LED does not have an activity indicating function The other three LEDs indicate system status as follows PWR red lights up when the device has power TD green lights up when the device is transmittin...

Страница 4: ...leasing the push button allows you to make a selection in the menu The menu is used to select and run an application s operating modes Select a mode by navigating through the main menu multicolored LE...

Страница 5: ...e Click 512 but are only signaled on the attached contact closure device For data verification purposes the event data messages pushed by SmartSensor HD are translated into readable text strings This...

Страница 6: ...se motorists in a timely and effective way There are three basic methods to synchronize this trigger Trigger at an ETA to the sign Trigger at a point upstream of the sign Trigger as soon as possible A...

Страница 7: ...ETA ms Duration fixed 1 2 3 4 6 5 variable Time to Sign SetbackDistance_ft V_fps 1 Front edge of vehicle enters beam 2 Back edge of vehicle leaves beam The time from point 1 to point 2 is variable and...

Страница 8: ...he length and speed of the vehicle 3 Detection event is generated one second after the vehicle leaves the beam This one second delay is fixed 4 Output is activated when front edge of vehicle reaches t...

Страница 9: ...ration the device will need to be changed to submode 1 The Click 512 is then configured using the Click Supervisor software See the knowledge base article 0514 Installing and Using Click Supervisor fo...

Страница 10: ...e made configuration changes on a driver and saved it to the Click device the word current will appear after that driver to indicate the driver that is currently loaded onto the device Note Changing a...

Страница 11: ...er unless another device on the network has the same ID number The Comm subtab allows you to configure how the Click device communicates see the figure and table below Setting Description Baud Rate Al...

Страница 12: ...12 tab you will see ten tabs The first is labeled Overall This tab allows you to configure values for the speed and length thresholds see the figure and table below Note Values in Click Supervisor wil...

Страница 13: ...d text strings There are nine other tabs you can access They correspond to the eight possible contact closure outputs the Click 512 can be configured to deal with The other eight tabs are labeled O1 t...

Страница 14: ...elapse before the activation of the output after the detection If the trigger sync method is Automatic this setting controls the time that will elapse before the activation of the output after the ET...

Отзывы: