WIFI-LPT100-B User Manual
22
/
60
2) Respond
Table 10 Response of Query Command
No.
Name
Bytes
Description
1
Head
1
Fixed value: 0xFF
2
Length
2
length from Length (not
include) to Check word (not
included)
3
Command byte
11
type of command, 0x81:
response of query
4
number of AP
1
The number of AP searched
5
SSID1
SSID of router 1
6
end mark
1
Fixed: 0x00
7
strength of signal 1
1
signal strength of router 1
network. Range: 0~100 (related
real value: 0%~100%)
8
end mark
2
0x0D, 0x0A
…
…
…
…
M
SSID n
SSID of router n
M+1
end mark
1
Fixed: 0x00
M+2
Strength of signal n
1
signal strength of router n
network. Range: 0~100 (related
real value: 0%~100%)
M+3
end mark
2
0x0D, 0x0A
M+4
Check word
1
the sum of the bytes from Head
(not included) to Check word
(not included)
For example:
Phone to Module (HEX): FF 00 01 01 02
Module reply to phone (HEX): FF 00 14 81 02 54 45 53 54 31 00 40 0D 0A 54
45 53 54 32 00 37 0D 0A 1F
Description: Phone send query command to module to query the information
of router. And the information replied from module is that: there are 2 routers, the
SSID of router 1 is “TEST1”, its signal strength is
64%. And the SSID of router 2 is
“TEST2”, its signal strength
is 55%
Note
: the information is order according to the signal strength of router.
3
)
Set Command
Table 11 Set Command
No.
Name
Bytes
Description