User Manual
79
Battery Module
Nominal Voltage/Capacity per Module
38.4V/ 3.84KWH
Expand Capability
String: Max. 1000V [20*3.84kWh], Optional 1500V [34*3.84kWh]
DOD Recommended
90%
Max. Charge/Discharge Current
100A Continual
Recommend Charge/Discharge Current
100A Continual
Communication Protocol/Connector Type
CAN/ RJ45
Power Connection Type
Amphenol Original with Lock
Dimension [W×H×D]
435×734×95mm per module
Weight
40kg
Charge Temperature Range
0-45
℃
Discharge Temperature Range
-20-55
℃
Ingress Protection
IP21
Installation Method
Rack Mounted
Cables Connection Method
Connection at front
Warranty
10 years or 8,000 cycles @90% DOD
Appendix
9.1 Technical Parameters
Module specification
Sub-Master BMS
Operation Voltage
150-1000V/ 700-1500V (Need to confirm upon order)
Max. Charge/Discharge Current
100A
Recommend Charge/Discharge Current
100A
Pre-charge, Over-Less Voltage/ Over-Less Temperature Protection
Functions
Cells Balancing/ SOC-SOH calculationetc
Communication Protocol/Connector Type
CAN/RS485 ModBus, TCP/ IP/ RJ45/ WiFi/ LAN/ GPRS
Power Connection Type
Amphenol MC4
User Interface
LCD Display (Optional, need to be confirmed upon order)
Dimension [W×H×D]
465×180×319mm
Weight
10kg
Operating Temperature
-20-55
℃
Ingress Protection
IP21
Installation Method
Rack Mounted
Warranty
10 years