ENGLISH
EN
13
PPLIMW15428C | 2019 / 06 Watts
5. INSTALLATION TYPES (HEATING
/
COOLING)
TYPE 1
In this configuration:
• Pair first the thermostat (master) with the Central before pairing the other devices
(configured as heating devices).
• The actuators regulate on thermostat temperature.
TYPE 2
In this configuration:
• Pair first the thermostat (master - configured as a heating device) with the Central
before pairing the other devices.
• The other devices regulate on thermostat temperature.
Warning!
In this installation type, the thermostat (MASTER) must be in regulation Air
mode (not floor or Air + Floor)
ROOM 1
ROOM 1
Master-Thermostat
Master
and/or
and/or
and/or
and/or
and/or
Actuators
Содержание Vision BT-CT02 RF
Страница 25: ......
Страница 49: ...www wattswater eu...
Страница 73: ...www wattswater eu...
Страница 97: ...www wattswater eu...
Страница 121: ...www wattswater eu...
Страница 145: ...www wattswater eu...
Страница 169: ...www wattswater eu...
Страница 193: ...www wattswater eu...
Страница 217: ...www wattswater eu...