background image

This device complies with part 15 of the FCC Rules. Operation 

is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause 

undesired operation.
This device complies with Industry Canada licence-exempt RSS 

standard(s). Operation is subject to the following two condi-

tions: (1) this device may not cause interference, and (2) this 

device must accept any interference, including interference that 

may cause undesired operation of the device.
Lé present appareil est conforme aux CNR d'Industrie 

Canada applicables aux appareils radio exempts de licence. 

L'exploitation est autorisée aux deux conditions suivantes : (1) 

l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur 

de l'appareil doit accepter tout brouillage radioélectrique subi, 

même si le brouillage est susceptible d'en compromettre le 

fonctionnement.
Any changes or modifications of this product not approved by 

the manufacturer could void the user’s authority to operate the 

equipment.
This equipment complies with IC RSS-102 radiation exposure 

limits set forth for an uncontrolled environment. This equipment 

should be installed and operated with minimum distance 20cm 

between the radiator & your body.
Under Industry Canada regulations, this radio transmitter may 

only operate using an antenna of a type and maximum (or 

lesser) gain approved for the transmitter by Industry Canada. To 

reduce potential radio interference to other users, the antenna 

type and its gain should be so chosen that the equivalent iso-

tropically radiated power (e.i.r.p.) is not more than that neces-

sary for successful communication.

IOM-PW-SmartStream-C_D

Installation Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-7

Product Specification Tables  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7

Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Feed Water Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Installation Procedure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Lamp and Quartz Sleeve Replacement . . . . . . . . . . . . . . . . . . . . . . 11

Disinfection Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13

Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Controller Identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Overview of Screens  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-20

Controller Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Warranty and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Table of Contents

Original Instructions

 

Read this Manual BEFORE using this 

equipment. Failure to read and follow 

all safety and user information can 

result in death, serious personal injury, 

property damage, or damage to the equipment. 

Keep this Manual for future reference.

WARNING

!

This system contains a UV-C emitter (UV lamp)
•  

DO NOT

 look directly at the UV lamp while it 

is ON.  Permanent serious eye damage could 

occur.

•  

DO NOT

 use if UV lamp, housing or any part of 

system is damaged.

•   Any damage to UV lamp or misuse of system 

could result in escape of dangerous UV-C radia-

tion.  UV-C radiation even in small doses can 

cause harm to eyes and skin.  

•  

NEVER

 use UV lamp if it is removed from the 

housing (enclosure).   

•  

ALWAYS

 turn 

OFF

 and disconnect (unplug) sys-

tem from power supply 

BEFORE

 replacing UV 

lamp or performing any repairs or maintenance.

WARNING

!

Installation, Operation and 
Maintenance Manual

 

254 Nanometer Germicidal  

UV Disinfection Systems

Models

PWC012 PWC016 PWC020 PWC025 PWC040 PWC050 

PWD012 PWD016 PWD020 PWD025 PWD040 PWD050

SmartStream

 UV 

Chemical Free Disinfection of Water

SmartStream  UV is certified by the Water Quality
Association (WQA) to NSF/ANSI Standard 372 
for lead free.

UV

Содержание SmartStream UV PWC012

Страница 1: ...and its gain should be so chosen that the equivalent iso tropically radiated power e i r p is not more than that neces sary for successful communication IOM PW SmartStream C_D Installation Precautions 3 System Specifications 4 7 Product Specification Tables 5 7 Dimensions 8 Feed Water Requirements 9 Installation Procedure 9 10 Maintenance 11 Lamp and Quartz Sleeve Replacement 11 Disinfection Proce...

Страница 2: ...roper method of operating this equipment ask your supervisor consult this manual access www ___________ com or contact us at _____________________ Product Identification Model Date of purchase Serial Date of Installation Please record your product s identification and purchase information which will help in the event you have questions or need any service ect This system should only be installed a...

Страница 3: ... units can be installed as a final disinfection method within a water treatment system train or as pretreat ment to protect sensitive components such as reverse osmo sis membranes from bio films The injection of chemicals into the water should be done on the outlet of the SmartStream system to ensure UV light degrada tion of the chemical or the introduction of turbidity within the UV feedstream do...

Страница 4: ...ear any device or break out area that would be adversely effected by water DO NOT install this system higher in elevation than 10 000 feet above sea level DO NOT install the system backwards with the feed water line connected to the outlet DO NOT install where system is exposed to harsh chemicals or may be subjected to being struck by moving equipment carts mops or any other item that may cause da...

Страница 5: ...9 3 lpm FLOW RATE 40mJ 95 UVT EOL usgpm liters min 9 6 gpm 36 3 lpm 12 6 gpm 47 7 lpm 15 6 gpm 59 0 lpm 18 8 gpm 71 2 lpm 30 0 gpm 113 6 lpm 37 5 gpm 141 9 lpm STANDARD NPT INLET OUTLET PORTS 1 NPT M 3 4 NPT F Combo Ports 1 5 NPT M 1 NPT F Combo Ports OPTIONAL BSP T INLET OUTLET PORTS 1 BSP M 3 4 BSP F Combo Ports 1 5 BSP M 1 BSP F Combo Ports CHAMBER MATERIAL 316L SS CONTROLLER MOUNTING On chambe...

Страница 6: ...gation detailed system status messages maintenance diagnostic and dealer programmable with website contact information QR codes LAMP LIFE MONITOR Display on graphic touch screen auto reset with new lamp UV SENSOR Available Option 4 20mA OUTPUT With UV Sensor Option VISUAL ALARM Animated icons and text messages on graphic display AUDIBLE ALARM Yes AUDIBLE ALARM MUTE Yes ALARM RELAY SOLENOID CONTACT...

Страница 7: ...22 00 16 3 34 27 86 28 89 7 63 8 29 3 00 4 50 16 00 26 00 20 3 34 31 40 32 43 7 63 8 29 3 00 4 50 16 00 30 00 25 3 34 31 64 32 67 8 13 8 29 3 00 4 50 16 00 30 00 40 3 34 43 02 44 05 8 13 8 29 3 00 4 50 16 00 41 00 50 3 34 50 14 51 17 8 13 8 29 3 00 4 50 16 00 48 00 The weight of each model when it is full of water is as follows 33 lbs Model WUV12 35 lbs Model WUV16 38 lbs Model WUV20 43 lbs Model ...

Страница 8: ...the quartz sleeve nut onto the quartz sleeve port thread and tighten hand tight 16 Install the ultraviolet lamp into the quartz sleeve DO NOT touch the lamp with your fingers Hold it with a paper towel 17 Insert the lamp power lead wire into the receptacle on the lamp s glow cap 18 If using the solenoid valve safety shut off feature connect the solenoid valve s power wires to the solenoid valve po...

Страница 9: ...upply valves 20 Check for leaks and repair as needed 21 Plug in power cord 22 Open outlet valve 23 Purge air from plumbing system out of the nearest cold water faucet to the UV system 24 Open inlet and outlet isolation valves on water heaters s and turn water heaters back on 25 Perform the disinfection procedure within this manual on page 11 ...

Страница 10: ...readed port 4 8 Remove the quartz sleeve from the reactor chamber 5 9 Fully insert a new quartz sleeve into the reactor chamber and install the o ring over the quartz sleeve Press the o ring down over the quartz sleeve until it is seated in the bevel of the stainless steel reactor chamber s threaded port 10 Install the quartz sleeve nut onto the threaded port of the reactor chamber Screw the nut o...

Страница 11: ...Flush 2 reactor chamber volumes of water through the UV system then stop and let the solution remain in the UV sys tem for 30 minutes 6 After 30 minutes flow enough water through the system to flush all of the residual chlorine from the system During this time DO NOT exceed the rated flow rate of the UV system If applicable install a new activated carbon cartridge into the prefilter housing at thi...

Страница 12: ... Sleeve for 12 GPM C D Series 20 9 531mm 6 1 7300867 UV Quartz Sleeve for 16 GPM C D Series 24 8 631mm 6 1 7300868 UV Quartz Sleeve for 20 25 GPM C D Series 28 4 722mm 6 1 7300869 UV Quartz Sleeve for 40 GPM C D Series 39 8 1011mm 6 1 7300870 UV Quartz Sleeve for 50 GPM C D Series 46 9 1192mm 7 1 T7402102 UV Quartz Sleeve O Ring 8 1 7300861 UV Lamp Assembly for 12 GPM C D Series 8 1 7300862 UV Lam...

Страница 13: ...nts within this manual UV sensor fouled or defective Clean or replace UV sensor Low power to lamp Replace controller Lamp intensity does not increase with water flow Confirm flow switch is functioning White or milky colored water Air in water from new prefilter or quartz sleeve replacement Flow water through the system until water runs clear Lamp out alarm ON Filaments broken in lamp Replace lamp ...

Страница 14: ...or Button for silencing the alarm Button for overriding the alarm relay LED Status Indicator Series C Lamp Cable LED Display Days remaining and lamp dimming System Status Indicator LED Green operation normal Red lamp failure Amber Lamp life will expire within 29 days Alarm Relay Bypass Button bypasses as long as button is held Audible Alarm Mute Button mutes alarm for 24 hours ...

Страница 15: ...r the specific system installed along with QR codes for those items Set Up Screen Allows the user to select a language as well as the bypass ing and silencing of alarms Touching the house icon from any of these sub screens will return the user to the Home Screen Lamp Warm Up Screen Once Startup Screen system checks are complete the lamp warm up screen will appear and automatically complete the lam...

Страница 16: ... via this screen The system will continue to the Home Screen when a UV sensor is not found and display the warning message The lamp identifies its self via radio frequency If the wrong lamp is used in a system this message will appear during start up Every 15 seconds the screen will change from the Invalid Lamp Type message to the Name of Contractor to message Touch on the QR Code to display the c...

Страница 17: ...ondition the system should be checked immediately for proper operation The system will reset an annual calendar upon replacement of a new lamp When 29 days remain on any given lamp a yellow warning will appear Upon zero days remaining on the lamp a red warning will appear Replace lamp at this time The user will be notified if a lamp failure occurs Upon a lamp failure condition the alarm relay will...

Страница 18: ...relay to the nor mal operating position and return to the Set Up Screen Touch No to return to the set up screen with the alarm relay in the alarmed condition Touching the speaker icon will bring up a con firmation screen Touch Yes to mute the audible alarm for 24 hours and return to the Set Up Screen Touch No to return to the Set Up Screen with the alarm not muted Alarm relay output is bypassed Au...

Страница 19: ...s will provide the system model number along with the model number and QR codes for replacement lamps and quartz sleeves Touching the QR Code icons on the Lamp and Sleeve Replacement Screen will enlarge them If there are no buttons touched over a 30 seconds period the system will go back to the Home Screen To return from the full screen QR code touch the screen ...

Страница 20: ...mmon Normally Open Alarm Relay B Left to Right Normally Closed Common Normally Open Power Input AC 100 240 VAC 50 60HZ Series D Right Ground to Chassis Center Flow Switch Left Antenna Wire 4 20mA Transmitter Left is Loop Right is Loop Future Accessories Top Cat 5 Future Accessories Bottom Cat 5 UV Sensor Alarm Relay A Left to Right Normally Closed Common Normally Open Alarm Relay B Left to Right N...

Страница 21: ...21 Notes ...

Страница 22: ...22 Notes ...

Страница 23: ...23 Notes ...

Страница 24: ...c environments indoors that are within ambient temperature limitations free from external water contact where relative humidity is below 95 non condensing and that are noncorrosive to the product s materials of construction including its electronic components The use of any unauthorized or inappropriate replacement parts will void this limited warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRES...

Отзывы: