2

Introduction

Thank you for purchasing the Watts SmartStream™ line of ultra-

violet disinfection systems.   SmartStream™ provides protection 

against microbiological contamination in water for residential and 

commercial applications. Disinfection of water with SmartStream™ 

is a simple, rapid physical process. When contaminated water is 

exposed to SmartStream's™ 254 nanometer UV light, the UV light 

penetrates the cell walls of microorganisms, disrupts their genetic 

deoxyribonucleic acid (DNA) material, and quickly inactivates mi-

croorganisms by destroying their ability to replicate and infect. This 

device conforms to the applicable provisions of the Code of Federal 

Regulations (CFR) requirements including, Title 21, Chapter 1, Sub-

chapter J, Radiological Health.
SmartStream™ will provide safe and productive operation as long 

as it is used in accordance with the instructions in this manual and 

is properly maintained by adequately trained and supervised people. 

Owners should not permit anyone to touch this equipment unless 

they are over 18 years of age, are adequately trained and super-

vised, and have read and understand this manual.  Owners should 

also ensure that no unauthorized personnel come in contact with 

this equipment.  READ THIS MANUAL carefully, learn how to use 

and service this equipment correctly, and strictly follow all of the 

instructions contained in this manual and the requirements of local, 

state and federal law. This manual should be considered a perma-

nent part of your machine and should be kept available for easy 

reference by any user.
If this equipment, or any of its parts, becomes damaged or needs 

repair, stop using the equipment and contact an experienced ser-

vice individual immediately.  If the warning labels or this manual are 

misplaced, damaged or illegible, or if you require additional copies, 

please contact customer service at _________ for these items at no 

charge.
If you are ever uncertain about a particular task or the proper 

method of operating this equipment, ask your supervisor, consult 

this manual, access www.___________.com, or contact us at 

_____________________.

Product Identifi cation

Model:

Date of purchase:

Serial #:

Date of Installation:

Please record your product’s identifi cation and purchase information 

which will help in the event you have questions or need any service.

ect.

This system should only be installed and maintained by a qual-
ifi ed professional. Observe all national, state, and local plumb-
ing and building codes when installing the system.

   

NOTICE

Understanding Safety Information

This manual contains safety and use instructions that must be 

followed during the installation, commissioning, operation, care 

and maintenance, and service of the SmartStream™.  All respon-

sible personnel must read this manual prior to working with this 

instrument, and should familiarize themselves with the following 

safety symbols, signals, and pictorials.

This is a safety-alert symbol. The 

safety alert symbol is shown alone or 

used with a signal word (DANGER, 

WARNING, or CAUTION), a pictorial 

and/or a safety message to identify 

hazards.
When you see this symbol alone or with 

a signal word on your equipment or in 

this Manual, be alert to the potential for 

death or serious personal injury.

This symbol identifies hazards which, if 

not avoided, will result in death or seri-

ous injury. 

This symbol identifies hazards which, 

if not avoided, could result in death or 

serious injury. 
  
This symbol identifies hazards which, 

if not avoided, could result in minor or 

moderate injury. 
  
This symbol identifies practices, actions, 

or failure to act which could result in 

property damage or damage to the 

equipment.

This pictorial alerts you to the need to 

read the Manual. 

This pictorial alerts you to electricity, 

electrocution and shock hazards.   

This pictorial alerts you to Ultraviolet 

(UV) hazards

This pictorial alerts you to connect the 

System only to a properly grounded 

receptacle protected by a Ground Fault 

Circuit Interrupter (GFCI)

WARNING

!

CAUTION

!

NOTICE

DANGER

!

!

Safety signal words have the following meaning:

Pictorials used on the equipment and in this 
Manual have the following meanings:

UV

Содержание SmartStream UV PWC012

Страница 1: ...and its gain should be so chosen that the equivalent iso tropically radiated power e i r p is not more than that neces sary for successful communication IOM PW SmartStream C_D Installation Precautions 3 System Specifications 4 7 Product Specification Tables 5 7 Dimensions 8 Feed Water Requirements 9 Installation Procedure 9 10 Maintenance 11 Lamp and Quartz Sleeve Replacement 11 Disinfection Proce...

Страница 2: ...roper method of operating this equipment ask your supervisor consult this manual access www ___________ com or contact us at _____________________ Product Identification Model Date of purchase Serial Date of Installation Please record your product s identification and purchase information which will help in the event you have questions or need any service ect This system should only be installed a...

Страница 3: ... units can be installed as a final disinfection method within a water treatment system train or as pretreat ment to protect sensitive components such as reverse osmo sis membranes from bio films The injection of chemicals into the water should be done on the outlet of the SmartStream system to ensure UV light degrada tion of the chemical or the introduction of turbidity within the UV feedstream do...

Страница 4: ...ear any device or break out area that would be adversely effected by water DO NOT install this system higher in elevation than 10 000 feet above sea level DO NOT install the system backwards with the feed water line connected to the outlet DO NOT install where system is exposed to harsh chemicals or may be subjected to being struck by moving equipment carts mops or any other item that may cause da...

Страница 5: ...9 3 lpm FLOW RATE 40mJ 95 UVT EOL usgpm liters min 9 6 gpm 36 3 lpm 12 6 gpm 47 7 lpm 15 6 gpm 59 0 lpm 18 8 gpm 71 2 lpm 30 0 gpm 113 6 lpm 37 5 gpm 141 9 lpm STANDARD NPT INLET OUTLET PORTS 1 NPT M 3 4 NPT F Combo Ports 1 5 NPT M 1 NPT F Combo Ports OPTIONAL BSP T INLET OUTLET PORTS 1 BSP M 3 4 BSP F Combo Ports 1 5 BSP M 1 BSP F Combo Ports CHAMBER MATERIAL 316L SS CONTROLLER MOUNTING On chambe...

Страница 6: ...gation detailed system status messages maintenance diagnostic and dealer programmable with website contact information QR codes LAMP LIFE MONITOR Display on graphic touch screen auto reset with new lamp UV SENSOR Available Option 4 20mA OUTPUT With UV Sensor Option VISUAL ALARM Animated icons and text messages on graphic display AUDIBLE ALARM Yes AUDIBLE ALARM MUTE Yes ALARM RELAY SOLENOID CONTACT...

Страница 7: ...22 00 16 3 34 27 86 28 89 7 63 8 29 3 00 4 50 16 00 26 00 20 3 34 31 40 32 43 7 63 8 29 3 00 4 50 16 00 30 00 25 3 34 31 64 32 67 8 13 8 29 3 00 4 50 16 00 30 00 40 3 34 43 02 44 05 8 13 8 29 3 00 4 50 16 00 41 00 50 3 34 50 14 51 17 8 13 8 29 3 00 4 50 16 00 48 00 The weight of each model when it is full of water is as follows 33 lbs Model WUV12 35 lbs Model WUV16 38 lbs Model WUV20 43 lbs Model ...

Страница 8: ...the quartz sleeve nut onto the quartz sleeve port thread and tighten hand tight 16 Install the ultraviolet lamp into the quartz sleeve DO NOT touch the lamp with your fingers Hold it with a paper towel 17 Insert the lamp power lead wire into the receptacle on the lamp s glow cap 18 If using the solenoid valve safety shut off feature connect the solenoid valve s power wires to the solenoid valve po...

Страница 9: ...upply valves 20 Check for leaks and repair as needed 21 Plug in power cord 22 Open outlet valve 23 Purge air from plumbing system out of the nearest cold water faucet to the UV system 24 Open inlet and outlet isolation valves on water heaters s and turn water heaters back on 25 Perform the disinfection procedure within this manual on page 11 ...

Страница 10: ...readed port 4 8 Remove the quartz sleeve from the reactor chamber 5 9 Fully insert a new quartz sleeve into the reactor chamber and install the o ring over the quartz sleeve Press the o ring down over the quartz sleeve until it is seated in the bevel of the stainless steel reactor chamber s threaded port 10 Install the quartz sleeve nut onto the threaded port of the reactor chamber Screw the nut o...

Страница 11: ...Flush 2 reactor chamber volumes of water through the UV system then stop and let the solution remain in the UV sys tem for 30 minutes 6 After 30 minutes flow enough water through the system to flush all of the residual chlorine from the system During this time DO NOT exceed the rated flow rate of the UV system If applicable install a new activated carbon cartridge into the prefilter housing at thi...

Страница 12: ... Sleeve for 12 GPM C D Series 20 9 531mm 6 1 7300867 UV Quartz Sleeve for 16 GPM C D Series 24 8 631mm 6 1 7300868 UV Quartz Sleeve for 20 25 GPM C D Series 28 4 722mm 6 1 7300869 UV Quartz Sleeve for 40 GPM C D Series 39 8 1011mm 6 1 7300870 UV Quartz Sleeve for 50 GPM C D Series 46 9 1192mm 7 1 T7402102 UV Quartz Sleeve O Ring 8 1 7300861 UV Lamp Assembly for 12 GPM C D Series 8 1 7300862 UV Lam...

Страница 13: ...nts within this manual UV sensor fouled or defective Clean or replace UV sensor Low power to lamp Replace controller Lamp intensity does not increase with water flow Confirm flow switch is functioning White or milky colored water Air in water from new prefilter or quartz sleeve replacement Flow water through the system until water runs clear Lamp out alarm ON Filaments broken in lamp Replace lamp ...

Страница 14: ...or Button for silencing the alarm Button for overriding the alarm relay LED Status Indicator Series C Lamp Cable LED Display Days remaining and lamp dimming System Status Indicator LED Green operation normal Red lamp failure Amber Lamp life will expire within 29 days Alarm Relay Bypass Button bypasses as long as button is held Audible Alarm Mute Button mutes alarm for 24 hours ...

Страница 15: ...r the specific system installed along with QR codes for those items Set Up Screen Allows the user to select a language as well as the bypass ing and silencing of alarms Touching the house icon from any of these sub screens will return the user to the Home Screen Lamp Warm Up Screen Once Startup Screen system checks are complete the lamp warm up screen will appear and automatically complete the lam...

Страница 16: ... via this screen The system will continue to the Home Screen when a UV sensor is not found and display the warning message The lamp identifies its self via radio frequency If the wrong lamp is used in a system this message will appear during start up Every 15 seconds the screen will change from the Invalid Lamp Type message to the Name of Contractor to message Touch on the QR Code to display the c...

Страница 17: ...ondition the system should be checked immediately for proper operation The system will reset an annual calendar upon replacement of a new lamp When 29 days remain on any given lamp a yellow warning will appear Upon zero days remaining on the lamp a red warning will appear Replace lamp at this time The user will be notified if a lamp failure occurs Upon a lamp failure condition the alarm relay will...

Страница 18: ...relay to the nor mal operating position and return to the Set Up Screen Touch No to return to the set up screen with the alarm relay in the alarmed condition Touching the speaker icon will bring up a con firmation screen Touch Yes to mute the audible alarm for 24 hours and return to the Set Up Screen Touch No to return to the Set Up Screen with the alarm not muted Alarm relay output is bypassed Au...

Страница 19: ...s will provide the system model number along with the model number and QR codes for replacement lamps and quartz sleeves Touching the QR Code icons on the Lamp and Sleeve Replacement Screen will enlarge them If there are no buttons touched over a 30 seconds period the system will go back to the Home Screen To return from the full screen QR code touch the screen ...

Страница 20: ...mmon Normally Open Alarm Relay B Left to Right Normally Closed Common Normally Open Power Input AC 100 240 VAC 50 60HZ Series D Right Ground to Chassis Center Flow Switch Left Antenna Wire 4 20mA Transmitter Left is Loop Right is Loop Future Accessories Top Cat 5 Future Accessories Bottom Cat 5 UV Sensor Alarm Relay A Left to Right Normally Closed Common Normally Open Alarm Relay B Left to Right N...

Страница 21: ...21 Notes ...

Страница 22: ...22 Notes ...

Страница 23: ...23 Notes ...

Страница 24: ...c environments indoors that are within ambient temperature limitations free from external water contact where relative humidity is below 95 non condensing and that are noncorrosive to the product s materials of construction including its electronic components The use of any unauthorized or inappropriate replacement parts will void this limited warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRES...

Отзывы: