System Features

C Series Controller With Lamp Dimming 

FCC ID: 2AFJT-SMARTSTREAM

GPM Rating

12

16

20

25

40

50

IC: 20623-SMARTSTREAM

System Model #

PWC012

PWC016

PWC020

PWC025

PWC040

PWC050

Universal Power Input

4

4

4

4

4

4

316 SS Chamber

4

4

4

4

4

4

Audible Alarm

4

4

4

4

4

4

Lamp On Indicator

4

4

4

4

4

4

Glow Cap Lamp Indicator

4

4

4

4

4

4

Lamp Life Timer with 3-digit display

4

4

4

4

4

4

Automatic Lamp Shut Off when  

Removed from the Chamber (wireless)

4

4

4

4

4

4

Lamp Dimming

4

4

4

4

4

4

Integrated Bracket Mounting

4

4

4

4

4

4

Alarm Contact Relay (for solenoid valve)

4

4

4

4

4

4

UV Sensor Input

4

4

4

4

4

4

4-20 mA Output (If UV Sensor is used)

4

4

4

4

4

4

12V Power for Chamber Cooling Fan

4

4

4

4

4

4

Graphic Display
Total System Hours Indicator

Product Specifications Table

MODEL

PWC012

PWC016

PWC020

PWC025

PWC040

PWC050

FLOW RATE @ 16mJ

 

(95%UVT @ EOL) 

(may be hydraulically limited)

usgpm 

liters/min

24.0  gpm 

90.8  lpm

31.5  gpm 

119.2  lpm

39.0  gpm 

147.6  lpm

46.9  gpm 

177.5  lpm

75.0  gpm 

283.9  lpm

93.8  gpm 

355.0  lpm

FLOW RATE @ 30mJ

 

(95%UVT @ EOL)

usgpm 

liters/min

12.8  gpm 

48.4  lpm

16.8  gpm 

63.6  lpm

20.8  gpm 

78.7  lpm

25.0  gpm 

94.6  lpm

40.0  gpm 

151.4  lpm

50.0  gpm 

189.3  lpm

FLOW RATE @ 40mJ

 

(95%UVT @ EOL)

usgpm 

liters/min

9.6  gpm 

36.3  lpm

12.6  gpm 

47.7  lpm

15.6  gpm 

59.0  lpm

18.8  gpm 

71.2  lpm

30.0  gpm 

113.6  lpm

37.5  gpm 

141.9  lpm

STANDARD NPT INLET / OUTLET PORTS

1"NPT-M / 3/4"NPT-F 

Combo Ports

1.5"NPT-M / 1"NPT-F 

Combo Ports

OPTIONAL BSP-T INLET / OUTLET 

PORTS

1"BSP-M / 3/4"BSP-F 

Combo Ports

1.5"BSP-M / 1"BSP-F 

Combo Ports

CHAMBER MATERIAL

316L SS

CONTROLLER MOUNTING

On chamber bracket or remote from chamber

INPUT VOLTAGE

100 to 240VAC   50/60Hz

SYSTEM MAX NOMINAL INPUT POWER 

(Watts)

47

58

67

67

100

118

LAMP MAX NOMINAL ELECTRICAL 

POWER (Watts)

45

55

64

64

95

112

LAMP TECHNOLOGY

Quartz glass low pressure lamp / ozone free / true pre-heat starting / glow-cap indicator

WIRELESS LAMP KEY

Standard

LAMP DIMMING / FLOW SWITCH

Standard

CHAMBER COOLING FAN

Applicable Option

SYSTEM DISPLAY TYPE

Seven segment three digit LED

LAMP LIFE MONITOR

3-digit LED Display, auto-reset with new lamp

UV SENSOR

Available Option

4-20mA OUTPUT

With UV Sensor Option

VISUAL ALARM

Multi-color status LED

AUDIBLE ALARM

Yes

AUDIBLE ALARM MUTE

Yes

ALARM RELAY / SOLENOID CONTACTS

Yes - 24V 5 Amp Maximum

ALARM RELAY MANUAL OVER-RIDE

Yes

MAXIMUM AMBIENT AIR TEMPERATURE /  HUMIDITY

50°C   ( 122°F)  /  95% RH (non-condensing)

INLET WATER TEMPERATURE RANGE

34°F ( 1°C) to 113°F ( 45°C)

MAX WATER PRESSURE

125psi (861 kPa)

SHIPPING WEIGHT

19LB (9KG)

19LB (9KG)

20LB (9KG)

25LB (11KG)

27LB (12KG)

29LB (13KG)

Содержание SmartStream UV PWC012

Страница 1: ...and its gain should be so chosen that the equivalent iso tropically radiated power e i r p is not more than that neces sary for successful communication IOM PW SmartStream C_D Installation Precautions 3 System Specifications 4 7 Product Specification Tables 5 7 Dimensions 8 Feed Water Requirements 9 Installation Procedure 9 10 Maintenance 11 Lamp and Quartz Sleeve Replacement 11 Disinfection Proce...

Страница 2: ...roper method of operating this equipment ask your supervisor consult this manual access www ___________ com or contact us at _____________________ Product Identification Model Date of purchase Serial Date of Installation Please record your product s identification and purchase information which will help in the event you have questions or need any service ect This system should only be installed a...

Страница 3: ... units can be installed as a final disinfection method within a water treatment system train or as pretreat ment to protect sensitive components such as reverse osmo sis membranes from bio films The injection of chemicals into the water should be done on the outlet of the SmartStream system to ensure UV light degrada tion of the chemical or the introduction of turbidity within the UV feedstream do...

Страница 4: ...ear any device or break out area that would be adversely effected by water DO NOT install this system higher in elevation than 10 000 feet above sea level DO NOT install the system backwards with the feed water line connected to the outlet DO NOT install where system is exposed to harsh chemicals or may be subjected to being struck by moving equipment carts mops or any other item that may cause da...

Страница 5: ...9 3 lpm FLOW RATE 40mJ 95 UVT EOL usgpm liters min 9 6 gpm 36 3 lpm 12 6 gpm 47 7 lpm 15 6 gpm 59 0 lpm 18 8 gpm 71 2 lpm 30 0 gpm 113 6 lpm 37 5 gpm 141 9 lpm STANDARD NPT INLET OUTLET PORTS 1 NPT M 3 4 NPT F Combo Ports 1 5 NPT M 1 NPT F Combo Ports OPTIONAL BSP T INLET OUTLET PORTS 1 BSP M 3 4 BSP F Combo Ports 1 5 BSP M 1 BSP F Combo Ports CHAMBER MATERIAL 316L SS CONTROLLER MOUNTING On chambe...

Страница 6: ...gation detailed system status messages maintenance diagnostic and dealer programmable with website contact information QR codes LAMP LIFE MONITOR Display on graphic touch screen auto reset with new lamp UV SENSOR Available Option 4 20mA OUTPUT With UV Sensor Option VISUAL ALARM Animated icons and text messages on graphic display AUDIBLE ALARM Yes AUDIBLE ALARM MUTE Yes ALARM RELAY SOLENOID CONTACT...

Страница 7: ...22 00 16 3 34 27 86 28 89 7 63 8 29 3 00 4 50 16 00 26 00 20 3 34 31 40 32 43 7 63 8 29 3 00 4 50 16 00 30 00 25 3 34 31 64 32 67 8 13 8 29 3 00 4 50 16 00 30 00 40 3 34 43 02 44 05 8 13 8 29 3 00 4 50 16 00 41 00 50 3 34 50 14 51 17 8 13 8 29 3 00 4 50 16 00 48 00 The weight of each model when it is full of water is as follows 33 lbs Model WUV12 35 lbs Model WUV16 38 lbs Model WUV20 43 lbs Model ...

Страница 8: ...the quartz sleeve nut onto the quartz sleeve port thread and tighten hand tight 16 Install the ultraviolet lamp into the quartz sleeve DO NOT touch the lamp with your fingers Hold it with a paper towel 17 Insert the lamp power lead wire into the receptacle on the lamp s glow cap 18 If using the solenoid valve safety shut off feature connect the solenoid valve s power wires to the solenoid valve po...

Страница 9: ...upply valves 20 Check for leaks and repair as needed 21 Plug in power cord 22 Open outlet valve 23 Purge air from plumbing system out of the nearest cold water faucet to the UV system 24 Open inlet and outlet isolation valves on water heaters s and turn water heaters back on 25 Perform the disinfection procedure within this manual on page 11 ...

Страница 10: ...readed port 4 8 Remove the quartz sleeve from the reactor chamber 5 9 Fully insert a new quartz sleeve into the reactor chamber and install the o ring over the quartz sleeve Press the o ring down over the quartz sleeve until it is seated in the bevel of the stainless steel reactor chamber s threaded port 10 Install the quartz sleeve nut onto the threaded port of the reactor chamber Screw the nut o...

Страница 11: ...Flush 2 reactor chamber volumes of water through the UV system then stop and let the solution remain in the UV sys tem for 30 minutes 6 After 30 minutes flow enough water through the system to flush all of the residual chlorine from the system During this time DO NOT exceed the rated flow rate of the UV system If applicable install a new activated carbon cartridge into the prefilter housing at thi...

Страница 12: ... Sleeve for 12 GPM C D Series 20 9 531mm 6 1 7300867 UV Quartz Sleeve for 16 GPM C D Series 24 8 631mm 6 1 7300868 UV Quartz Sleeve for 20 25 GPM C D Series 28 4 722mm 6 1 7300869 UV Quartz Sleeve for 40 GPM C D Series 39 8 1011mm 6 1 7300870 UV Quartz Sleeve for 50 GPM C D Series 46 9 1192mm 7 1 T7402102 UV Quartz Sleeve O Ring 8 1 7300861 UV Lamp Assembly for 12 GPM C D Series 8 1 7300862 UV Lam...

Страница 13: ...nts within this manual UV sensor fouled or defective Clean or replace UV sensor Low power to lamp Replace controller Lamp intensity does not increase with water flow Confirm flow switch is functioning White or milky colored water Air in water from new prefilter or quartz sleeve replacement Flow water through the system until water runs clear Lamp out alarm ON Filaments broken in lamp Replace lamp ...

Страница 14: ...or Button for silencing the alarm Button for overriding the alarm relay LED Status Indicator Series C Lamp Cable LED Display Days remaining and lamp dimming System Status Indicator LED Green operation normal Red lamp failure Amber Lamp life will expire within 29 days Alarm Relay Bypass Button bypasses as long as button is held Audible Alarm Mute Button mutes alarm for 24 hours ...

Страница 15: ...r the specific system installed along with QR codes for those items Set Up Screen Allows the user to select a language as well as the bypass ing and silencing of alarms Touching the house icon from any of these sub screens will return the user to the Home Screen Lamp Warm Up Screen Once Startup Screen system checks are complete the lamp warm up screen will appear and automatically complete the lam...

Страница 16: ... via this screen The system will continue to the Home Screen when a UV sensor is not found and display the warning message The lamp identifies its self via radio frequency If the wrong lamp is used in a system this message will appear during start up Every 15 seconds the screen will change from the Invalid Lamp Type message to the Name of Contractor to message Touch on the QR Code to display the c...

Страница 17: ...ondition the system should be checked immediately for proper operation The system will reset an annual calendar upon replacement of a new lamp When 29 days remain on any given lamp a yellow warning will appear Upon zero days remaining on the lamp a red warning will appear Replace lamp at this time The user will be notified if a lamp failure occurs Upon a lamp failure condition the alarm relay will...

Страница 18: ...relay to the nor mal operating position and return to the Set Up Screen Touch No to return to the set up screen with the alarm relay in the alarmed condition Touching the speaker icon will bring up a con firmation screen Touch Yes to mute the audible alarm for 24 hours and return to the Set Up Screen Touch No to return to the Set Up Screen with the alarm not muted Alarm relay output is bypassed Au...

Страница 19: ...s will provide the system model number along with the model number and QR codes for replacement lamps and quartz sleeves Touching the QR Code icons on the Lamp and Sleeve Replacement Screen will enlarge them If there are no buttons touched over a 30 seconds period the system will go back to the Home Screen To return from the full screen QR code touch the screen ...

Страница 20: ...mmon Normally Open Alarm Relay B Left to Right Normally Closed Common Normally Open Power Input AC 100 240 VAC 50 60HZ Series D Right Ground to Chassis Center Flow Switch Left Antenna Wire 4 20mA Transmitter Left is Loop Right is Loop Future Accessories Top Cat 5 Future Accessories Bottom Cat 5 UV Sensor Alarm Relay A Left to Right Normally Closed Common Normally Open Alarm Relay B Left to Right N...

Страница 21: ...21 Notes ...

Страница 22: ...22 Notes ...

Страница 23: ...23 Notes ...

Страница 24: ...c environments indoors that are within ambient temperature limitations free from external water contact where relative humidity is below 95 non condensing and that are noncorrosive to the product s materials of construction including its electronic components The use of any unauthorized or inappropriate replacement parts will void this limited warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRES...

Отзывы: