Watts SmartStream

 UV systems are engineered with the high-

est quality components. If at anytime a component needs to be 

replaced, use only parts recommended and supplied by Watts.  

DO

 

NOT

 add components to or remove components from this 

system.
The UV lamp is rated for 9000 hours under normal operating 

conditions and should be replaced annually to keep the UV 

intensity at the highest possible output. Quartz sleeves should 

be cleaned as needed or replaced as needed to guarantee the 

highest possible UV transmittance into the water.
Use only Watts supplied UV lamps and quartz sleeves for your 

specific model. Failure to do so may result in system failure and 

will void all warranty. 

DO

 

NOT

 use this system in a manner that it is not intended for. 

This purifier is only for use in water applications where the feed 

water, installation environment and installation method meets 

the requirements within this manual.
The system must be properly sized. 

DO

 

NOT

 exceed the rated 

flow rate capacity of the system. Flow controllers are available 

from Watts to ensure system's rated flow is not exceeded.
Follow all product safety labeling.
•  

DO

 

NOT

 let the system freeze. System damage may result.

•   Install the system on a flat, and level surface.
•   The quality of the water to be treated must meet the feed 

water guidelines within this manual. Failure to ensure proper 

pretreatment will result in inadequate disinfection.

   

NOTICE

Using SmartStream

 with other water treatment equipment

SmartStream

 UV units can be installed as a final disinfection 

method within a water treatment system train or as pretreat-

ment to protect sensitive components, such as reverse osmo-

sis membranes, from bio-films. 
The injection of chemicals into the water should be done on the 

outlet of the SmartStream

 system to ensure UV light degrada-

tion of the chemical or the introduction of turbidity within the UV 

feedstream does not occur.
A 5 micron particle filter should always be installed immediately 

before the SmartStream

 system. 

Be certain that the feed water meets all criteria within the Feed 

Water Specifications section of this manual.

 

This appliance can be used by people aged from 18 years and 

above and persons with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they have 

been given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved.  

Children shall not play with the appliance.  Cleaning and user 

maintenance shall not be made by children.

   

NOTICE

DO

 

NOT

 rely solely on this system to make water safe to drink. 

SmartStream

 UV disinfection systems are intended to be used 

as part of a well designed water treatment system. Water that 

contains microbiological contamination should be tested regu-

larly to ensure its quality and safety at the point of use.

DO

 

NOT

 touch the quartz sleeve with your fingers. Hold it with  

a paper towel.

DO

 

NOT

 touch the lamp with your fingers. Hold it with  

a paper towel.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

This device conforms to the applicable provisions of the Code 

of Federal Regulations (CFR) requirements including, Title 21, 

Chapter 1, Subchapter J, Radiological Health.

Содержание SmartStream UV PWC012

Страница 1: ...and its gain should be so chosen that the equivalent iso tropically radiated power e i r p is not more than that neces sary for successful communication IOM PW SmartStream C_D Installation Precautions 3 System Specifications 4 7 Product Specification Tables 5 7 Dimensions 8 Feed Water Requirements 9 Installation Procedure 9 10 Maintenance 11 Lamp and Quartz Sleeve Replacement 11 Disinfection Proce...

Страница 2: ...roper method of operating this equipment ask your supervisor consult this manual access www ___________ com or contact us at _____________________ Product Identification Model Date of purchase Serial Date of Installation Please record your product s identification and purchase information which will help in the event you have questions or need any service ect This system should only be installed a...

Страница 3: ... units can be installed as a final disinfection method within a water treatment system train or as pretreat ment to protect sensitive components such as reverse osmo sis membranes from bio films The injection of chemicals into the water should be done on the outlet of the SmartStream system to ensure UV light degrada tion of the chemical or the introduction of turbidity within the UV feedstream do...

Страница 4: ...ear any device or break out area that would be adversely effected by water DO NOT install this system higher in elevation than 10 000 feet above sea level DO NOT install the system backwards with the feed water line connected to the outlet DO NOT install where system is exposed to harsh chemicals or may be subjected to being struck by moving equipment carts mops or any other item that may cause da...

Страница 5: ...9 3 lpm FLOW RATE 40mJ 95 UVT EOL usgpm liters min 9 6 gpm 36 3 lpm 12 6 gpm 47 7 lpm 15 6 gpm 59 0 lpm 18 8 gpm 71 2 lpm 30 0 gpm 113 6 lpm 37 5 gpm 141 9 lpm STANDARD NPT INLET OUTLET PORTS 1 NPT M 3 4 NPT F Combo Ports 1 5 NPT M 1 NPT F Combo Ports OPTIONAL BSP T INLET OUTLET PORTS 1 BSP M 3 4 BSP F Combo Ports 1 5 BSP M 1 BSP F Combo Ports CHAMBER MATERIAL 316L SS CONTROLLER MOUNTING On chambe...

Страница 6: ...gation detailed system status messages maintenance diagnostic and dealer programmable with website contact information QR codes LAMP LIFE MONITOR Display on graphic touch screen auto reset with new lamp UV SENSOR Available Option 4 20mA OUTPUT With UV Sensor Option VISUAL ALARM Animated icons and text messages on graphic display AUDIBLE ALARM Yes AUDIBLE ALARM MUTE Yes ALARM RELAY SOLENOID CONTACT...

Страница 7: ...22 00 16 3 34 27 86 28 89 7 63 8 29 3 00 4 50 16 00 26 00 20 3 34 31 40 32 43 7 63 8 29 3 00 4 50 16 00 30 00 25 3 34 31 64 32 67 8 13 8 29 3 00 4 50 16 00 30 00 40 3 34 43 02 44 05 8 13 8 29 3 00 4 50 16 00 41 00 50 3 34 50 14 51 17 8 13 8 29 3 00 4 50 16 00 48 00 The weight of each model when it is full of water is as follows 33 lbs Model WUV12 35 lbs Model WUV16 38 lbs Model WUV20 43 lbs Model ...

Страница 8: ...the quartz sleeve nut onto the quartz sleeve port thread and tighten hand tight 16 Install the ultraviolet lamp into the quartz sleeve DO NOT touch the lamp with your fingers Hold it with a paper towel 17 Insert the lamp power lead wire into the receptacle on the lamp s glow cap 18 If using the solenoid valve safety shut off feature connect the solenoid valve s power wires to the solenoid valve po...

Страница 9: ...upply valves 20 Check for leaks and repair as needed 21 Plug in power cord 22 Open outlet valve 23 Purge air from plumbing system out of the nearest cold water faucet to the UV system 24 Open inlet and outlet isolation valves on water heaters s and turn water heaters back on 25 Perform the disinfection procedure within this manual on page 11 ...

Страница 10: ...readed port 4 8 Remove the quartz sleeve from the reactor chamber 5 9 Fully insert a new quartz sleeve into the reactor chamber and install the o ring over the quartz sleeve Press the o ring down over the quartz sleeve until it is seated in the bevel of the stainless steel reactor chamber s threaded port 10 Install the quartz sleeve nut onto the threaded port of the reactor chamber Screw the nut o...

Страница 11: ...Flush 2 reactor chamber volumes of water through the UV system then stop and let the solution remain in the UV sys tem for 30 minutes 6 After 30 minutes flow enough water through the system to flush all of the residual chlorine from the system During this time DO NOT exceed the rated flow rate of the UV system If applicable install a new activated carbon cartridge into the prefilter housing at thi...

Страница 12: ... Sleeve for 12 GPM C D Series 20 9 531mm 6 1 7300867 UV Quartz Sleeve for 16 GPM C D Series 24 8 631mm 6 1 7300868 UV Quartz Sleeve for 20 25 GPM C D Series 28 4 722mm 6 1 7300869 UV Quartz Sleeve for 40 GPM C D Series 39 8 1011mm 6 1 7300870 UV Quartz Sleeve for 50 GPM C D Series 46 9 1192mm 7 1 T7402102 UV Quartz Sleeve O Ring 8 1 7300861 UV Lamp Assembly for 12 GPM C D Series 8 1 7300862 UV Lam...

Страница 13: ...nts within this manual UV sensor fouled or defective Clean or replace UV sensor Low power to lamp Replace controller Lamp intensity does not increase with water flow Confirm flow switch is functioning White or milky colored water Air in water from new prefilter or quartz sleeve replacement Flow water through the system until water runs clear Lamp out alarm ON Filaments broken in lamp Replace lamp ...

Страница 14: ...or Button for silencing the alarm Button for overriding the alarm relay LED Status Indicator Series C Lamp Cable LED Display Days remaining and lamp dimming System Status Indicator LED Green operation normal Red lamp failure Amber Lamp life will expire within 29 days Alarm Relay Bypass Button bypasses as long as button is held Audible Alarm Mute Button mutes alarm for 24 hours ...

Страница 15: ...r the specific system installed along with QR codes for those items Set Up Screen Allows the user to select a language as well as the bypass ing and silencing of alarms Touching the house icon from any of these sub screens will return the user to the Home Screen Lamp Warm Up Screen Once Startup Screen system checks are complete the lamp warm up screen will appear and automatically complete the lam...

Страница 16: ... via this screen The system will continue to the Home Screen when a UV sensor is not found and display the warning message The lamp identifies its self via radio frequency If the wrong lamp is used in a system this message will appear during start up Every 15 seconds the screen will change from the Invalid Lamp Type message to the Name of Contractor to message Touch on the QR Code to display the c...

Страница 17: ...ondition the system should be checked immediately for proper operation The system will reset an annual calendar upon replacement of a new lamp When 29 days remain on any given lamp a yellow warning will appear Upon zero days remaining on the lamp a red warning will appear Replace lamp at this time The user will be notified if a lamp failure occurs Upon a lamp failure condition the alarm relay will...

Страница 18: ...relay to the nor mal operating position and return to the Set Up Screen Touch No to return to the set up screen with the alarm relay in the alarmed condition Touching the speaker icon will bring up a con firmation screen Touch Yes to mute the audible alarm for 24 hours and return to the Set Up Screen Touch No to return to the Set Up Screen with the alarm not muted Alarm relay output is bypassed Au...

Страница 19: ...s will provide the system model number along with the model number and QR codes for replacement lamps and quartz sleeves Touching the QR Code icons on the Lamp and Sleeve Replacement Screen will enlarge them If there are no buttons touched over a 30 seconds period the system will go back to the Home Screen To return from the full screen QR code touch the screen ...

Страница 20: ...mmon Normally Open Alarm Relay B Left to Right Normally Closed Common Normally Open Power Input AC 100 240 VAC 50 60HZ Series D Right Ground to Chassis Center Flow Switch Left Antenna Wire 4 20mA Transmitter Left is Loop Right is Loop Future Accessories Top Cat 5 Future Accessories Bottom Cat 5 UV Sensor Alarm Relay A Left to Right Normally Closed Common Normally Open Alarm Relay B Left to Right N...

Страница 21: ...21 Notes ...

Страница 22: ...22 Notes ...

Страница 23: ...23 Notes ...

Страница 24: ...c environments indoors that are within ambient temperature limitations free from external water contact where relative humidity is below 95 non condensing and that are noncorrosive to the product s materials of construction including its electronic components The use of any unauthorized or inappropriate replacement parts will void this limited warranty THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRES...

Отзывы: