GB
9
4 4 2 1
L
TH
Output
5.4
Room Temperature – Direct Plug In
As an option you can plug in a room thermostat to the ClimaticControl-HC. Direct plug in of a room thermostat op-
timizes the operational time of the circulation pump and even the supply flow temperature depending on the condi-
tions in the main room.
5.4.1 Mixed circuit (Water Floor), standard room thermostat, wired type
If a wired type of a standard room thermostat is plugged in and the preset room temperature is reached in
the room, the under floor circulation pump switches off after pump delay time. (PUMP:
System parame-
ters:
pump delay time)
WFHT-BASIC
WFHT-LCD
MILUX xxx
5.4.2 Direct circuit (Panel Heater), standard room thermostat, wired type
If a second circulation pump is installed and managed by the ClimaticControl-HC (Inst:
System param-
eters:
installation type, “
2P.x
”), you can install a second wired room thermostat to manage the working of
the high temperature pump.
This pump will work in the following way: If the preset room temerature is reached in the room the High
water temperature circulation pump switches off after pump delay time. (PUMP:
System parameters:
pump delay time)
WFHT-BASIC
WFHT-LCD
MILUX xxx
< °C
Fig. 6
< °C
Fig. 7
In
1
In
2
4
2
In
1
In
2
4
2
In
1
In
2
4
2
4 4 2 1
TH
Output
In
1
In
2
4
2