manualshive.com logo in svg
background image

7

Setting The Controller 

Demand Regeneration

You won’t have to worry about vacation settings or extra guests be-

cause the controller measures water usage and regenerates based 

on need. The appliance will regenerate using only the necessary 

amount of water and salt. If power has been turned off, your appli-

ance will retain programmed settings indefinitely.

1. Entering Your Hardness Setting

See Page 13 for determining your setting number. The water hard-

ness setting number shown in the digital readout will increase 1 grain 

each time you push the “SET” button. After 90 grains, the readout 

will return to 1, and continue to count up from 1 until the display 

number matches the hardness number. After 5 seconds the display 

will change to show “gallons remaining (x 100)”. To recheck the hard-

ness, touch “SET.”

2. Gallons Remaining

After setting water hardness, gallons remaining until the next auto-

matic regeneration is shown in the digital display. NOTE: Gallons 

remaining are in hundreds. 12=1,200 gallons.

3. Recharge/Regeneration Status

Regeneration cycle numbers are shown during regeneration. The 

read-out will flash with the cycle number. The flashing regeneration 

numbers are:
  First cycle:  

 

(C1) First Backwash

  Second & Third cycles:  

(C2) Brine/Slow Rinse

  Fourth cycle: 

 

(C3) Second Backwash

  Fifth cycle:  

 

(C4) Brine Refill

  Sixth cycle: 

 

(HO) Service

To quickly advance through the regeneration cycles, press and hold 

the REGENERATE button for 2 seconds. Wait for the cycle to begin, 

after 20 seconds press and hold the REGENERATE button until 

the cycle number changes (about 2 seconds). Each cycle can be 

advanced in this manner.

4. WATERMIZER

®

The waterMizer

®

 wheel will turn whenever water is being used.  

See Figure 10.

5. REGENERATE

To start an immediate regeneration, press The “REGENERATE” but-

ton and hold for 3 seconds. The REGENERATE button is used when 

starting your water conditioner, to start an immediate regeneration, 

or to restore capacity if you have run out of salt. If your appliance has 

run out of salt, you may not have soft water available. Remove the 

salt lid and add salt. Wait two hours, then press the “REGENERATE” 

button and hold for 3 seconds. See Figure 10.

6) POWERCLEAN™

The POWERCLEAN™ feature is a service/maintenance step for 

water supplies that have an excessive amount of iron. Activating 

this feature is a simple push of the POWERCLEAN™ button on the 

controller.
POWERCLEAN™ will appear in the display when this feature is acti-

vated. The appliance will regenerate every other day with five pounds 

of salt. Leave the POWERCLEAN™ feature on for a minimum of 

two weeks. The frequent regeneration will eliminate iron buildup in 

the resin bed. The use of salt with an iron cleaning agent or iron out 

cleaner is recommended for continuous use as a preventive measure 

against iron fouling of the resin bed. To deactivate this feature, 

simply press the POWERCLEAN™ button. Use this feature every six 

months as a part of your routine maintenance procedure to ensure a 

long service life for your water treatment appliance. See Figure 10.

Hardness Settings

1.  Hold down “SET” for 3 seconds to enter basic customer settings 

mode.

2.  “Set Hardness” and a default hardness number is now displayed. 

Pressing and releasing the “CHANGE” button will increase the 

hardness setting # by one. As a short cut, pressing and releasing 

the powerClean™ button will advance the display by 10. However, 

the CHANGE button alone can be used to advance the display 

one digit at a time to the correct number. If “Gallons x 100” was 

selected, 01 = 100 gallons. If “Liters x 1000” was selected, 01 = 

1,000 liters. Pressing and releasing “SET” will save the hardness 

number and put the appliance into operation. The appliance is 

now ready for use as recommended. To fine-tune the program-

ming further…

Содержание PWSCAB30K Pure Water

Страница 1: ...ed for operating parameters to ensure proper use with your water supply Table of Contents Pages How To Get the Maximum Efficiency From Your Appliance 2 Checklist Before Installation 2 Do s and Don ts...

Страница 2: ...ed to verify that your appliance is right for the job See Page 4 3 Water Supply Flow Rate 5 gallons per minute is recommended as minimum 4 Drain Drain appliance to floor drain or washer drain To preve...

Страница 3: ...s Valves To simplify installation and servicing a one piece or a three way by pass valve system is recommended when installing your appliance A bypass system also provides access to untreated water wh...

Страница 4: ...here is a threaded connection to facilitate repairing a potential leak in one of your soldered joints 3 To prevent heat damage to the plastic pipe threads of the adapter prepare the copper tail assemb...

Страница 5: ...5 Reference Illustrations Figure 7 Figure 8 Plugging In Transformer Do not plug transformer into an outlet that is controlled by on off switch Adding Salt To The Brine Cabinet Figure 9...

Страница 6: ...lve in the Service position See Figure 6 6 Connect Overflow Line The overflow line is used to direct excess water to a floor drain if the brine tank fills with too much water or the appliance malfunct...

Страница 7: ...ut ton and hold for 3 seconds The REGENERATE button is used when starting your water conditioner to start an immediate regeneration or to restore capacity if you have run out of salt If your appliance...

Страница 8: ...s Pressing and releasing the SET button will advance programming to the next step 6 If Gallons was chosen 12 is now displayed If Liters was chosen 24 is displayed Pressing and releasing the CHANGE but...

Страница 9: ...9 Controller Layout Figure 10...

Страница 10: ...abinet Figure 11 Item Description QTY 1 Valve Cover Assembly 1 2 Salt Port Cover 1 3 12 Volt Transformer Power Cord 1 4 Cabinet 1 5 2 Piece Overflow 1 6 Brine Tubing 3 8 18 7 Support Panel 1 8 Compute...

Страница 11: ...Adapter Assembly 1 2 3 4 I O Adapter O ring 2 3 Resin Tank Assembly empty 1 4 End Cap O ring 2 5 Drive End Cap Assembly w o motor magnet disc 1 6 Screw 4 7 O ring Small End Cap 1 8 Injector Assembly...

Страница 12: ...The gasket seals at its outer edges and between the inlet screen and nozzle opening These areas must be free of defects such as tears or pits and be free of debris 4 Injector Nozzle 1 Creates the vac...

Страница 13: ...ontroller The three wire assembly connecting the black wafer Hall Effect Sensor or the Controller board must not be severely bent folded over cut or broken Care should be taken when putting the Sensor...

Страница 14: ...Cap When assembling the Drain End Cap to the Main Valve Body care should be taken to make sure the small O ring is aligned with the opening in the Main Valve Body and that the large O ring stays in th...

Страница 15: ...alve retainer 5 push in and turn clockwise to unlock the retainer CAUTION Do not attempt to remove the retainer with the piston assembly in place This will damage the housing and or the retainer Push...

Страница 16: ...ession nuts are tight 2 Guide and Lock Set 1 Should not be loose 3 Float Grommet 2 Should keep float from moving up or down 4 Bell Float 1 5 Float Washer 1 6 Float Rod 1 7 Air Check Brine Well Assembl...

Страница 17: ...17 ITEM NO QTY DESCRIPTION 1 1 Fill Plug 2 2 O ring Parts Diagrams Fill Plug Assembly Tank Bottom Figure 18...

Страница 18: ...sehold plumbing system Repair the leak No read out in display Electric cord is unplugged Plug in transformer No electric power at outlet Check power source Make sure outlet is not controlled by a swit...

Страница 19: ...10 gpm 14 5 Pressure drop service flow rate of 4 gpm 4 0 psi Maximum flow rate to drain during regeneration gpm 2 0 Water Pressure minimum maximum psi 20 120 Controller type 4 Button Regeneration time...

Страница 20: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PER...